Green Brook PSKTRCDA2G Посібник із швидкого старту

Переглянути онлайн або завантажити pdf Посібник із швидкого старту для Аксесуари Green Brook PSKTRCDA2G. Green Brook PSKTRCDA2G 2 сторінки. Ip66 rated weatherproof rcd switched socket active

Green Brook PSKTRCDA2G Посібник із швидкого старту
Active -
Electrical latching - Needs to be reset after power failure.
PowerBreaker Protekt products are suitable for use outdoors in severe conditions of rain and water spray as
well as dust contamination to IP66 as defined by BS EN 60529. All products are for use with a 230V 50Hz supply.
INSTALLATION GUIDE - IMPORTANT
This product should be installed by a competent person and in accordance with the current IET Wiring
Regulations. If in doubt, consult a qualified electrician
Important -
Always disconnect the mains supply via the switch in the main fuse board or consumer unit before
commencing any electrical work.
Ensure that all terminal screws are fully tightened and that earth wires are sleeved and that no bare
wires are showing.
Cable glands must be used which maintain the IP rating. The warranty is invalid if IP rating is not
maintained.
1.
Ensure that mounting surface is flat and free from loose particles and dirt.
2.
Remove the fitted product by lifting the lid and unscrewing the two screws. Then remove the upper
portion from the back box by removing the 4 screws on installation. Please note that it is important to
use a screwdriver of a size that allows you to properly tighten these screws on installation.
3.
If necessary take the back box and drill a small hole through the drainage point that will be at the
lowest point when mounted. This is necessary to ensure that any residual moisture or condensation has
an escape route at the back of the box.
4.
Remove a suitable cable entry cover by pushing through from the inside of the back box.
If circumstances permit the best entry point for the supply cable is the bottom one.
5.
If cable entry is via 20mm conduit use the conduit gland to secure the conduit to the back box. If entry
of cable is to be direct use a suitable IP rated cable gland.
6.
Use only mains cable of sufficient rating for your application.
7.
Screw down the upper portion to the back box ensuring the collar seal is in position between the
mating surface.
See the instructions below on how to connect individual products.
8.
Mount the accessory onto the box using the screws as removed in step 2. Ensure the screws are
securely tightened.
Your weatherproof accessory is designed so that IP66 rating can be maintained when an appliance is
plugged into the socket. This is only achieved when the cover is pressed down firmly so that the cable runs
through the centre of the cable exit point, and is fully enclosed by the special seal. Always ensure that the
cover is located correctly in place. If in doubt, consult a qualified electrician.
1.
Connect the RCD Socket using the easy to follow wiring diagram below.
2.
If earth conductors are bare they must be sleeved with appropriate green/yellow sleeving.
N.B. Green/yellow earth wire may be connected to either earth terminal. Wiring insulation tests should be
completed before setting the PowerBreaker RCD Socket to avoid misleading instrument readings and
possible internal damage to the unit.
3.
Please follow the test procedure below & overleaf prior to each use.
PLEASE CARRY OUT THIS SIMPLE TEST PROCEDURE PRIOR TO EACH USE.
1.
Press Blue ON button.
2.
Clear window indicator around Blue button will turn Red and illuminate*.
3.
Press Grey Test button (T).
4.
Red window indicator and illumination will disappear*. This means the RCD has tripped successfully.
5.
To reset – press Blue ON button and use as a normal socket.
* If indicator fails to work, do not use and return to place of purchase.
IP66 Rated Weatherproof
RCD Switched Socket (Active)
- PSKTRCDA2G
Enclosure Installation Instructions
Wiring Instructions
Red (L)
or
Brown
P
K
rote
Green/Yellow (E)
Black
(N) or
Blue
t