8B.2. Fit the mounting studs to
the foundation plate and
secure in place with the
stud locknuts.
8B.3. Position the foundation
plate to allow for the pinion
to be unmeshed from the
rack when the gearbox has
to be removed.
Leave clearance under the
gearbox to allow for the
gearbox to be lowered if
the rack and pinion mesh is
too tight.
A gap of 3mm between
the rack and the pinion
must be maintained.
8B.4. Fit RAZ/Nylon/Steel angle rack as recommended by Centurion
Systems. Use height-adjustment nuts to obtain correct rack and
pinion mesh. Rack can be mounted above or below the pinion to
suit site conditions. Refer to illustration A1, A2, A3, B1, B2 and B2.
A1: Above pinion - RAZ rack
148 - 158
Foundation
plate
* Includes 3mm clearance
required between rack and pinion
B1: Above pinion - Nylon rack
148 - 158
Foundation
plate
* Includes 3mm clearance
required between rack and pinion
C1: Above pinion - Steel rack
146
Foundation
plate
* Includes 3mm clearance
required between rack and pinion
Flat bar welded
to foundation
plate and rail
Flat bar welded
to foundation
plate and rail
Flat bar welded
to foundation
plate and rail
Foundation
plate
Level this end
of the rack,
and fix
A2: Below pinion - RAZ rack
148 - 158
Raised
foundation
B2: Below pinion - Nylon rack
148 - 158
Raised
foundation
C2: Below pinion - Steel rack
Raised
foundation
Mounting
studs
Stud
locknut
(M10
half-height
nut)
Check that
the rack is
just resting
on the
pinion
Level this end
and fix
3mm
tooth gap
3mm
Lower
Foundation
plate
Foundation
plate
146
Foundation
plate