Major tech MTD33 Посібник з експлуатації - Сторінка 4
Переглянути онлайн або завантажити pdf Посібник з експлуатації для Мультиметр Major tech MTD33. Major tech MTD33 7 сторінок. 2000 counts digital multimeter
2.2.4 Resistance
Range
Accuracy
200Ω
± ( 1.0%+5 )
2000Ω
20kΩ
± ( 1.0%+3 )
200kΩ
2000kΩ
± (1.5%+3 )
Overload protection: F0.5A/600V fuse
2.2.5 Diode and Audible continuity test
Range
Description
Display read
approximately
forward voltage
of diode
Built-in buzzer
sounds
resistance is
less than 50Ω
Overload protection: F0.5A/600V fuse
3.
OPERATION
3.1
DC Voltage Measurement
1)
Connect the black test lead to the "COM" socket and red test lead to the
"VΩmA" socket.
2)
Set the selector switch to desired "V
3)
Measure the voltage by touch the test lead tips to the test circuit where the
value of voltage is needed.
4)
Read the result from the LCD panel. The polarity of the red lead connection will
be indicated along with the DC voltage value.
Note:
a)
If the voltage range is not known beforehand, set the selector switch to high
range and work down.
b)
When "1" or "-1" is display, over-range is being indicated and the selector switch
must be set to a higher range.
Resolution
0.1Ω
1Ω
10Ω
100Ω
1kΩ
Test condition
Forward DC current
approx. 10μA
Reversed DC voltage
approx. 1.8V
Open circuit voltage
if
approx. 1.8V
" position.