- 1. Installation/Maintenance/Use
- 2. Front Cover Removal
- 3. Mechanical Installation
- 4. Recessing Fans in the Wall
- 5. Surface Mounting Fans on Wall
- 6. Recessing Fans in Ceiling
- 7. Surface Mounting Fans on Ceiling
- 8. Electrical Installation
- 9. Optional Modules for Icon/Eco 230V
- 10. Troubleshooting Tip
- 11. Maintenance
- 12. Warranty
- 13. Range of Optional Modules
iCON Domestic Fan – 230V
Installation, Maintenance and Use
iCON Domestic Fans are available in 3 model sizes and can be fitted to a wall or ceiling. Each
fan requires a suitable size hole through the wall or ceiling which connects into a duct
venting to the outside. The external opening should be covered by a suitable external grill,
available separately from Airflow Developments Ltd.
Airflow iCON / iCON eco Model Options
72683501 - eco15 -100mm Axial Fan with maximum capacity of 18.6 l/sec.
72573602 - 15
-100mm Axial Fan with maximum capacity of 21 l/sec.
72591601 - 30
-100mm Mixed Flow Fan with maximum capacity of 32 l/sec
72591701 - 60
-150mm Mixed Flow Fan with maximum capacity of 72 l/sec
The iCON range can be used as a simple extract fan operated by a remote switch, or can be
fitted with an internal control module, available separately to give a range of control options
including timer, humidity, motion sensor, pull cord, trickle speed or combinations of these
functions. Optional modules are available separately and can be fitted at the time of
installation or retrofitted.
The iCON Fan has an IP X4 rating housing and is suitable for mounting in Zone 1 or 2 in
bathrooms, toilets, kitchens, utility rooms and inside shower cubicles as defined in Section
701 BS7161:2008 (IEEE wiring standards, 17
Building Regulations.
Do not place the ventilator near direct heat sources, e.g. radiant heaters, or where
temperatures can exceed 40°C (104°F).
th
Edition ). They also comply with the latest
Page 2 of 8