Major tech MT478 Посібник користувача - Сторінка 10

Переглянути онлайн або завантажити pdf Посібник користувача для Випробувальне обладнання Major tech MT478. Major tech MT478 16 сторінок. Voltage tester

Major tech MT478 Посібник користувача

5. Operation

5.1 Preparing the test
• Prior to every test, please ensure that the instrument is in perfect
condition:
• For example, keep an eye out for a broken housing or leaking batteries.
• Always carry out a function test before using the voltage tester, see
below.
• Check that the instrument is functioning properly(for example at a known
voltage source)before and after every test.
• If the safety of the user can not be guaranteed, switch off the instrument
and secure it to prevent unintentional usage.
Carrying out a function test
• Connect the voltage tester probe tips for 4 to10 seconds and then
disconnect.
• All LEDs should light up and the indicator probe side vibrates. All
segments are illuminated on the LCD display.
5.2 Preparing the test
• Connect both test probes with power source.
• As from a voltage of > 6V the voltage tester
switches on automatically.
• The voltage is displayed via LEDs.
• The different indicating signals of the voltage
detector (including the ELV lim indication)are not
to be used for measuring purposes.
• The voltage is also shown on the LCD display.
• For AC voltage, the "AC" is illuminated.
• For positive voltage, the "+" is illuminated.
• For negative voltage, the "-" is illuminated.
• In the case of DC voltage, the polarity of the indicated voltage relates
to the voltage tester probe tip
• Once the safety extra-low voltage (50V AC /120V DC) is reached or
exceeded, the "
main circuit failure, an acoustic signal is emitted.
• Once voltage is applied to the measuring instrument, press the HOLD
button, the LCD and LEDs display shows the recorded reading.
• To delete the recorded value, press the HOLD button once again. The
LCD and LED displays once again indicates the voltage currently
being applied to the probe tips.
" is illuminated, in the event of no battery power or
10