3. Press the ▲ "up button" or the ▼ "down button to find the
4. Press the ENTER/SAVE button to inquire whether to clear
Note: if the erasing unit needs not to be done, press ESC/
button to skip it and return back to the minor function
selection.
5. Press the ENTER/SAVE button again to clear up the data;
6. Press the ESC/
7.1.5. Introduction of other Functions:
1. Dielectric absorption ratio (DAR):
2. Polarization index (PI):
Lower insulation resistance tested takes a longer test time,
which would deteriorate the object under test. Thus, higher
DAR or PI (as close to 1) would create better insulation
grade of the object under test.
14
measurement time setting; LCD displays the following
picture respectively;
up the data or not; LCD displays the picture shown in
below:
LCD displays the picture shown in below:
then return back to the minor function selection.
page.
Ratio of insulation resistance between 1-min and 30-sec
1-min insulation resistance
DAR :
30-sec insulation resistance
Ratio of insulation resistance between 10-min and 1-min
10-min insulation resistance
PI :
1-min insulation resistance
button again to return back to the main