Major tech MT700 Інструкція з експлуатації - Сторінка 4
Переглянути онлайн або завантажити pdf Інструкція з експлуатації для Випробувальне обладнання Major tech MT700. Major tech MT700 16 сторінок. Voltage & current tester
1. Safety
1.1. lnternational Safety Symbols
WARNING of a potential danger, comply with instruction
manual.
CAUTION dangerous voltage, Danger of electrical shock.
Double insulation.
Important information. Consult the instruction sheet.
Hazardous Voltage.
Suitable for live working.
This product complies with the WEEE Directive (2012/19/EU).
Conforms to European Union Directives.
Measurement Category III is applicable to test and measuring
circuits connected to the distribution part of the building's low-
voltage mains installation.
Measurement Category IV is applicable to test and measuring
circuits connected at the source of the building's low-voltage
mains installation.
1.2. Safety Notes
• Reference, please use utmost attention.
• Do not exceed the maximum allowable input range of any function.
• Insulated personnel body protective equipment up to 1000V.
• The unauthorized persons are not to be allowed to disassemble the
voltage detector.
• The voltages marked on the voltage detector are nominal voltages or
nominal voltage ranges, and that the voltage detector is only to be
used on installations with the specified nominal voltages or nominal
voltage ranges.
1.3. WARNINGS
In order to avoid electrical shock, the valid safety and VOE
regulations regarding excessive contact voltages must receive
utmost attention, when working with voltages exceeding 120V
(60V) DC or 50V (25V) rms AC, the values in brackets are valid for
limited ranges (As for example medicine and agriculture).
Prior to measurement ensure that the test leads and the test
instrument are in perfect condition.
When using this instrument only the handles of the probes may be
touched-do not touch the probe tips.
4