Major tech MTD8 Посібник із швидкого старту

Переглянути онлайн або завантажити pdf Посібник із швидкого старту для Таймер Major tech MTD8. Major tech MTD8 2 сторінки. Digital programmable timer
Також для Major tech MTD8: Інструкції до програмування (2 сторінок)

Features:
Din Rail Mounted
Advanced weekly settings
Repeat programs with 16 ON/OFF settings, 18 pulse settings, and a manual ON/OFF switch
Lithium battery back up in the event of a power failure
MANUAL button changes between Manual ON/OFF, ON AUTO and AUTO OFF
Terminology: ON (Always ON), OFF (Always OFF), AUTO ON (Timer remains ON until the next OFF programmed
setting) / AUTO OFF (Timer remains OFF until next programmed ON setting and turns OFF as per programmed
OFF settings)
AUTO OFF – Automatically turns the timer ON and OFF as per the programmed settings
While programming any function, 30 seconds of inactivity will exit all setting menus
Technical Data:
Voltage Rating:
Voltage Limit:
Resistive Loads (Max):
Minimum Interval:
Countdown Interval:
18 Pulse Intervals:
Ambient temperature:
Ambient Humidity:
Weight:
Certification:
Dimensions:
L
N
L
OUT
36
Installation Instructions:
1.
All program settings explained below can be carried out before installation.
2.
Press Reset Button to activate timer (only required when first installed).
3.
Connect timer to 220V AC.
Setting the Clock:
1.
Hold down the
button to begin the process.
2.
While holding down the
of the screen.
3.
Continue holding down the
screen.
4.
Continue holding down the
screen.
5.
Release the
button and your time and date are set.
Weekly / Daily Programming:
1.
Press P button once and you will see "1 On" on the bottom left side of the screen. This will be the first day and time
you would like the timer to come on.
220V – 240V AC 50/60Hz
±10%
30A
4400W
1 minute
1 second – 99 minutes & 59 seconds
1 second – 59 minutes & 59 seconds
-10°C ~ 40°C
35%RH ~ 85%RH
150g
IEC60730-1, IEC60730-2-7
65
button press the D+ button until you see the required day of the week displayed at the top
button and press the H+ button until you see the required hour in the middle of the
button and press the M+ button until you see the required minutes in the middle of the
MTD8
DIGITAL PROGRAMMABLE TIMER
Wiring Diagram:
Live In
Circuit
Breaker
Neutral
Live In
N
L
ON
P
D+
H+
M+
RESET MANUAL
L
OUT
Live Load Out