Majorcom: PX-4120 Посібник з експлуатації - Сторінка 8

Переглянути онлайн або завантажити pdf Посібник з експлуатації для Підсилювач Majorcom: PX-4120. Majorcom: PX-4120 14 сторінок. 4 zone pa mixer amplifier

4.

OPERATION

For the four output terminals, please only use the COM and one of the others. When using 70V and
100V, the speaker must be with transformers. Moreover, and the total power of the speakers should
be less than the rated output power.
5.

MUTE FUNCTION

Mute Priority Description: MIC1 highest priority telephone remote MIC. Telephone and MIC1
priority can be reset via the rear panel short circuit terminals. Normally, MIC1 is with the highest priority.
6.

TROUBLE SHOOTING

Fault phenomenon
There is no sound output
when the line connection is good
Normal startup, the alarm triggered
In the normal use of all of a sudden
no sound output
>
>
The cause of the problem
1.No electricity or plug contact undesirable
2.The fuse was burn out
3.The volume is not open
4.No input signal
1. Load short circuit or damaged
2. Power supply voltage is not stable, too high or
too low
3. Overload
1. Temperature is too high, the machine in
temperature protection
2. Loose cable connection
8