10
EMAGP16
The remaining cable pair (N.C.) can be
used to double the +12V - GND pair, in
order to reach higher cable efficiency.
Both possibilities of connection between EMAGPE16and the
REMOTE ports in PXN matrices. Left- with the RJ45 to screw
terminals adapter / Right – without it, when no daisy-chained
units share the same REMOTE line
Usermanual V1.1
56, chemin
de la Flambère ·
F a x 3 3 ( 0 ) 5 6 1 3 1 8 7 7 3 · [email protected] ·
31300 Toulouse ·
FRANCE · T é l . 3 3 ( 0 ) 5 6 1 3 1 8 6 8 7
www.majorcom.fr
EMAGP16
EMAGPE16RJ45 connector pinout diagram CAN bus mode
o Connect as well the audio from the paging console micro-
phone (Audio signal + and - / OUT+ and -) to the + and –
terminals of one balanced audio input in the PXN matrix
(ground is common with CAN bus data ground). This will
be the input used in the PAGERS/DUCKERS module under
control by the paging station
o Power connector (2): if necessary, connect a backup power
supply (WP24-PSU model) (see section
bility terms and external power supply requirements
for further details)
• Check that both jumpers shown in the diagram below are positioned
in the CAN position. If the unit is the last one in the CAN bus
wiring line, insert as well J111-J112 jumper, 120 ohm terminal
resistor ON (closed contact position)
56, chemin
de la Flambère ·
31300 Toulouse ·
F a x 3 3 ( 0 ) 5 6 1 3 1 8 7 7 3 · [email protected] ·
11
5.2.2. Compati-
Usermanual V1.1
FRANCE · T é l . 3 3 ( 0 ) 5 6 1 3 1 8 6 8 7
www.majorcom.fr