Base Grille Water Filtration System
Model P2WG2L/P2RFWG2
Capacity
200 Gallons
(757 Liters)
Model
P2WG2/P2RFWG2
Capacity
200 Gallons
(757 Liters)
System
tested and certified
by NSF International
against
NSF/ANSI
Standard
42 for the reduction
of Chlorine
Taste and Odor, Particulate
Class I*; and against
NSF/ANSI
Standard
53 for the reduction
of Lead,
Mercury,
Benzene,
Toxaphene,
and O-dichlorobenzene.
This system
has been tested according
to NSF/ANSI
Standards
42 and 53 for the reduction
of the substances
listed below. The
concentration
of the indicated
substances
in water entering
the system
was reduced
to a concentration
less than or equal to the
permissible
limit for water leaving the system,
as specified
in NSF/ANSI
Standards
42 and 53.
Substance
Reduction
Aesthetic
Effects
Chlorine Taste/Odor
Particulate Class I*
Contaminant
Reduction
Lead: @ pH 6.5
Lead: @ pH 8.5
Mercury: @ pH 6.5
Mercury: @ pH 8.5
Benzene
O-Dichlorobenzene
Toxaphene
NSF Reduction
Average
Influent Challenge
Requirements
Influent
Concentration
50% reduction
1.909 mg/L
2.0 mg/L + 10%
85% reduction
9700000 #/mL
At east 1O,OOO part c es/mL
NSF Reduction
Average
Influent Challenge
Requirements
Influent
Concentration
0.010 mg/L
143.33 ug/L
0.15 mg/L + 10%
0.010 mg/L
140 ug/L
0.15 mg/L _+10%
0.002 mg/L
0.0058 mg/L
0.006 mg/L + 10%
0.002 mg/L
0.00646 mg/L
0.006 mg/L_+ 10%
0.005 mg/L
0.015 mg/L
0.015 mg/L _+10%
0.6 mg/L
1.83333 mg/L
1.8 mg/L _+10%
0.003 mg/L
0.016 mg/L
0.015 mg/L _+10%
Maximum
Average
Minimum %
Effluent
Effluent
Reduction
9.05 mg/L **
<9.95 mg/L
>97.4
2600 #/mL
62000 #/mL
>97.6
Maximum
Average
Effluent
Effluent
1.0 ug/L
1.0 ug/L
1.0 ug/L
1.0 ug/L
0.3 ug/L
0.0002 mg/L
1.4 ug/L
0.0004 mg/L
0.5 ug/L
0.0005 mg/L
4.8 ug/L
0.014 mg/L
1 ug/L
0.001 mg/L
Average %
Reduction
>97.4
>99.4
Minimum %
Average %
Reduction
Reduction
>99.3
>99.3
>99.3
99.3
>96.5
96.5
76.3
88.1
>96.5
>96.5
99.7
99.9
>93.2
>93.2
Test Parameters:
pH = 7.5 _+0.5 unless otherwise
noted.
Flow = 0.85 gpm (3.2 Lpm). Pressure
= 60 psig (413.7 kPa).
Temp. = 68°F to 71.6°F (20°C to 22°C). Rated service
capacity
= 200 gallons
(757 liters).
It is essential
that operational,
maintenance,
and filter
replacement
requirements
be carried
out for the product
to
perform
as advertised.
Use replacement
filter P2RFWG2,
part #4396841.
2008 suggested
retail price of $39.99
U.S.A./S54.95
Canada.
Prices are subject
to change without
notice.
Model P2WG2L/P2WG2:
Style
1 - When the filter indicator
reads 10%, order a new filter. When the indicator
reads 0%, it is
recommended
that you replace the filter.
Style 2 - When the filter indicator
changes
from green to yellow,
order a new filter. When the indicator
changes
from yellow to red,
it is recommended
that you replace the filter.
Style 3 - When the water filter status display changes
from
"GOOD"
to "ORDER,"
order a new filter. When the filter indicator
reads "REPLACE,"
it is recommended
that you replace the filter.
Style 4 - Press FILTER to check the status of your water filter. If
the filter indicator
light is yellow, order a new filter. If the filter
indicator
light is red, it is recommended
that you replace the filter.
Change
the water filter cartridge
every 6 months.
If the water
flow to the water dispenser
or ice maker decreases
noticeably
before 6 months
have passed,
replace the water filter cartridge
more often.
These contaminants are not necessarily in your water supply.
While testing was performed under standard laboratory
conditions, actual performance may vary.
The product is for cold water use only.
Do not use with water that is microbiologically unsafe or of
unknown quality without adequate disinfection before or after the
system.
Refer to the "Warranty" section for the Manufacturer's name,
address and telephone number.
Refer to the "Warranty" section for the Manufacturer's limited
warranty.
Application Guidelines/Water Supply Parameters
Water Supply
City or Well
Water Pressure
30 - 120 psi (207 - 827 kPa)
Water Temperature
33 ° - 100°F (0.6 ° - 37.8°C)
Service Flow Rate
0.85 gpm (3.2 Lpm) @ 60 psi
*Class I particle size: >0.5 um to <1 um
**Test requirement
is at least 100,OOO particles/mL
of AC Fine Test Dust.
® NSF is a registered trademark
of NSF International.
13