Before the initial operation of the waste water pump or after a long period of stagnation,
check that the shaft rotates freely when turned by hand. To this put a screwdriver in the
notch of the shaft end on the fan side and move the shaft. The strong initial rotational
resistance of the new pumps will come loose after running.
 Fill waste water pump fully through vent connection
 Tighten the cap nut of the filter housing by hand
Connection „IN"
Cap nut
 Connect waste water hose with proximity switch at „IN" of the coarse pre filter and
then connect to place of use (only use spiral hose)
 Connect „OUT" with sewer
 Establish power supply 230V, 50Hz (Schuko plug)