Filter Hepa H13 Filter Paper
The Hepa filter inside the machine, if present, guarantees air to be cleaned from excessive dust
and dirt. The filter must be periodically cleaned with a jet of compressed air at a distance of
about 20cm. It must be replaced after a maximum of 1,000 hours of use, in conjunction with the
cartridges motor brushes. The quality H13 HEPA filter paper, if maintained in good condition
and replaced as required above, it is able to protect against bacteria and external factors that
can go up to 99.997% of airborne particles.
Brush Motor (carbon brushes)
The motor brushes cartridge in the drive unit has a life of 500-600 hours of effective operation.
The duration of the same varies depending on the conditions of use and of cleaning the filter
and general maintenance of the appliance. It is needed to contact the service in order to
restore the brushes at the end of the cycle.
General Warnings:
Do NOT use this product for a different function from that to which it is intended: HAND DRYER
• Do not leave the appliance exposed to atmospheric conditions such as rain, sun, etc..
• Make no changes of any kind to the device
• Do not obstruct the air outlet or mouth
• Do not insert any object into the grid or the outlet air in case of failure and / or
malfunction, remove the mains and consult with the manufacturer or dealer.
Important Information
This product falls within the competence of the EC Directive 2002/96 (WEEE) on disposal of
electrical and electronic equipment. Complies with RoHS legislation.
Note:
This product should not be disposed with household waste.
Recycle it at the appropriate places.
Ask your Local Authority for recycling guidelines.
Trouble Shooting Guide
Cold air
Continuous operating
Not operating
change the heating element
on electric board decrease sensor sensibility by turning anticlockwise
the white trimmer on board
check all connections first and then change the electric board if
necessary.