CEP CT63 Посібник користувача - Сторінка 17
Переглянути онлайн або завантажити pdf Посібник користувача для Сенсорні термінали CEP CT63. CEP CT63 20 сторінок.
4
Power consumption
The following table shows you the power consumption of the CT63 / in different modes:
CT63 off (DTR low,
no TO-IN)
CT63 idle mode
CT63 low power
mode
Safety and Product Care
Please read the information in this section and the information in "Installation of the Modem", before
starting your integration work!
4.1 Safety instructions
PLEASE READ THESE SAFETY INSTRUCTIONS AND KEEP A COPY OF THEM.
Always ensure that use of the modem is permitted. The modem may present a hazard if used in proximity
to personal medical electronic devices. As a rule, the modem must not be used in hospitals, airports or
planes.
Never use the modem at a gas station, refueling point, blasting area or in any other environment where
explosives may be present.
Operating the modem close to other electronic devices, such as antennas, television sets, and radios may
cause electromagnetic interference.
This product is intended to be used with the antenna or other radiating element at least 20cm away from
any part of the human body. In applications where this rule cannot be applied, the application designer is
responsible for providing the SAR measurement test report and declaration.
You are responsible for observing your country's safety standards, and where applicable, the relevant
wiring rules.
4.2 General precautions
The CT63 Terminal as a stand alone item is designed for indoor use only. To use outside it must be
integrated into a weatherproof enclosure. Do not exceed the environmental and electrical limits as
specified in "Technical Data".
Avoid exposing the modem to lighted cigarettes, naked flames or to extreme hot or cold temperature.
Never try to dismantle the modem yourself. There are no components inside the modem that can be
serviced by the user. If you attempt to dismantle the modem, you may invalidate the warranty.
The CT63 Terminal must not be installed or located where the surface temperature of the plastic case may
exceed 85°C.
[mA] @ 5V
[mA] @ 12V
0,04
0,11
24,0
11,1
3,0
1,1
Table 6: Power consumption in idle and low power mode
[mA] @ 24V
0,22
6,2
1,0
17
[mA] @ 32V
0,29
5,5
0,9