The water tank MUST be filled with water before use: see previous chapter!
To ensure better reliability it is highly recommended to use decalcified or distilled water!
Empty the water tank and fog liquid tank before each transport and after each use
• Put the fogger on a flat and very stable surface and activate the brakes on the wheels.
• Use standard fog liquid to fill up the fog fluid canister. Close the canister to prevent dirt to enter the reservoir!
• Fill up the big water tank with distilled or decalcified water. On the inside of the tank there are several level
indications: fill the tank until the water level is between the minimum and maximum lines. (+/- 10 to 15 liters).
The water level indicators (9+10) will turn from [MIN] to [OK]
• Connect the fogger to a mains wall socket with earth connection
• Switch the fogger on and wait for about 2 to 3 minutes. (warm up time)
• You can now use the machine via the build-in timer or it can be controlled by DMX. (see below)
Setup menu
The setup menu is used to adjust the different parameters of the fogger.
The [MENU] button id used to browse the options of the setup menu:
A. [DMX512 Add] press the ▲/▼-buttons (13+14) to adjust the DMX-
address.
B. [FAN SPEED xxx%] press the ▲/▼-buttons (13+14) to adjust the fan
speed (1-100%) while the fogger is used in manual or in timer mode.
C. [VOLUME OUT xxx%] press the ▲/▼-buttons (13+14) to adjust the
output volume (1-100%) while the unit is used in manual / timer mode.
D. [INTERVAL SET xxxs] press the ▲/▼-buttons (13+14) to adjust the
interval time (10s→200s) while the fogger is used in timer mode.
E. [DURATION SET xxxs] press the ▲/▼-buttons (13+14) to adjust the
fog duration time (10s→100s) while the fogger is used in timer mode.
Controlled via DMX:
• Connect the unit to the DMX-line or use the WTR-DMX DONGLE for a wireless DMX setup.
• The DMX led (11) should be lit to indicate that a DMX-signal is received.
• Press the [MENU] button until the DMX address appears on the display
• Use the ▲/▼ buttons to set the desired DMX address.
• The unit uses 2 DMX channels:
• Channel 1: fan speed
• Channel 2: volume control
Controlled via the internal timer:
In this mode the fogger is not connected to a DMX-controller.
• First set the fan speed, volume, interval & duration time (see "setup menu" points B to E)
• Press the [X STOP]-button (15) to be sure that the fogger is in STOP mode.
• Press the [TIMER/▲]-button (13) to start the timer function.
• Press the [X STOP]-button (15) to stop the timer function.
Manual Control:
In this mode the fogger is not connected to a DMX-controller.
• First set the fan speed & output volume (see "setup menu" points B to C)
• Press the [X STOP]-button (15) to be sure that the fogger is in STOP mode.
• Press the [VOL/▼]-button (14) to start the manual working mode.
• Press the [X STOP]-button (15) to stop the manual working mode.
Instructions for refilling of the fog fluid canister
• Fog fluid should be added when the machine shows " FOG FLUID EMPTY "
• If needed follow the instructions for "Manual Control" to start up the machine again.
• Repeat the steps if the machine is not working immediately.
BRITEQ
®
!!! IMPORTANT !!!
The markings for min/max water levels must be respected!
(000-005: fan off
(000-005: no output
006-255: fan speed 1→100%)
006-255: volume 1→100%)