KitchenAid 9750520 Інструкція з монтажу - Сторінка 4

Переглянути онлайн або завантажити pdf Інструкція з монтажу для Діапазони KitchenAid 9750520. KitchenAid 9750520 5 сторінок. 30" electric freestanding range

Push cable,
located on rear of
range, up and into the two
hooks on the anti-tip
bracket. Check that cable is
secure in both hooks by
pulling cable towards range.
If cable comes out of hooks,
reposition cable to insure that
in both anti-tip bracket hooks.
final position.
cable fits securely
Slide range into
/17/
.
If installing the range in a mobile
home, you MUST secure the range to
the floor. Any method of securing the range is
adequate as long as it conforms to the standards
listed in the Mobile Home Installation
Instructions,
Panel A.
Place rack in oven. Place level on
rack, first side to side; then front to
back. If range is not level, adjust the leveling legs
up or down until the range is level.
Note: Oven must be level for satisfactory baking
conditions.
OFF
LO n
HI
each surface unit
control knob to "HI"
position. Check the
operation of the
cooktop elements and indicator lights.
Panel C
120
n
"88:88" should appear in the clock
disolav. Press the "Clock Set" button.
"TIME, HR AND-MIN will light up in the display.
"0:OO" will appear and the ":" will be flashing.
Press the number buttons for the correct time of
day. Press "Start/Enter"
button to start the clock.
Check the operation of the oven
element. Press the "BAKE" button.
"350"" will appear in the temperature display. The
ON, Bake Element, Outer Broil Element and
Oven Cavity symbols will light up in the display.
Press the "Start/Enter"
button.
The bottom element should glow red and the
indicator light should be on. The upper element
should become hot but not glow red. The oven
indicator light goes off when the oven is
preheated.
Press "Cancel/OFF"
button.
122
. Check the operation of the broil
element. Press the "BROIL" button.
"500"" will appear in the temperature display. The
ON, Inner and Outer Broil Elements and Oven
Cavity symbols will light up in the display. Press
the "Start/Enter"
button.
The top element should glow red and the
indicator light should be on.
Press the "Cancel/OFF"
button.
To get the most efficient use from your
new electric range, read your KitchenAid
Use and Care Guide. Keep Installation
Instructions
and Guide close to the
electric
range
for easy reference.
8.9. IO. 11.15. '6.
18.
IW
Numbers
correspond
to steps.
4-wire electrical connection
Use this wiring method for mobile homes and
whenever 4.wire installation is required.
U.L. llsted
conduit
connecxor
If appliance
is to be connected
directly
to fused disconnect
or circuit
breaker
box: Assemble a U.L.-listed conduit connector in
the conduit connector opening provided. Inset-f the
power supply cable through the conduit connector,
allowing enough slack to easily attach the wiring to
the terminal block.
U.L.-&ted
strain relief
show
I
----'ClampIng
screws
If a U.L.-listed,
40-ampere
range power supply
cord (pigtail)
is used:
Remove the knockout for the 40.ampere power
supply cord. Assemble a U.L.-listed strain relief in
the hole. Insert the power supply cord through the
strain relief, allowing enough slack to easily attach
the wiring to the terminal block.
Do not loosen the factory installed nuts already
installed on the terminal block.
Remove the grounding-link
screw from
the range frame. Save the grounding
screw. Bend up rhe grounding link so that it does
not contact the range.
Green -
Insulated
wire
l-z-l-
ding
lk.l
. -Connect the green grounding wire to the
range using the grounding screw
removed in Step B. The green grounding wire
must be attached first and must not contact any
other terminal.
Sllver-colored
terminal
block
screw
Green -
Insulated
wlre
- U.L. llsted strain
PI
relief shown.
. Connect the neutral (white) wire to the
center, silver-colored
terminal screw on
the terminal block. Connect the other two wires to
the outer terminals on the terminal block. Use ring-
type terminals only. Connect and securely tighten
the brass nuts that are provided on a plastic strip
attached to the range. Do Not loosen the factor-y
installed nuts already on the terminal.
Be sure that the nuts are installed tight.
(El
.
Tighten the strain relief clamping screws
or the locking ring and clamping screws
of the conduit connector. Replace the terminal
block cover.
Continue installation at Step 12, Panel B.