4.0 Operating Notes

A DD-8 should be connected where its fault protection/isolation or fan out capability can
be most effective. See Figure 4.1 below. Suggested positions include:
1. Between pieces of equipment that run from different power sources. Examples
of different power sources include:
• Stadium type shows where the dimmers are distributed in groups around the
• Outdoor shows where the console is run from a different power supply to the
2. At the input to a multi-piece equipment rack. If it is necessary to have complete
protection and isolation in a system then each receiving device must be
connected to an individual DD-8 output. If 12 channel dimmers in racks of six
are used, then one DD-8 per rack could isolate all of the dimmer inputs, provide
an isolated output for the next rack's DD-8, and still have one spare output.
3. To drive a DMX-512 control signal in multiple directions from a centre hub
point. A DD-8 mounted in a truss can be used to provide drive signals for
moving lights in separate segments of the truss.
Revision 2.0 - 5 July 1998
JANDS DD-8 DMX SPLITTER
stadium and each group is run from a local sub-board, transformer, or sub
station. In this case a separate DD-8 output should be used to drive separate
dimmer groups via individual cables. If this is not practical then a DD-8
should be placed at each dimmer group, to isolate that group.
dimmers. In this case the DD-8 should be placed just before the input to the
first receiving device on the line.
DMX-512 CONTROLLED DEVICES
Fig. 4.1 Typical JANDS DD-8 system configuration