KitchenAid KHHC2090SSS - Architect II 2.0 cu. ft. 1200 W Технічний паспорт

Переглянути онлайн або завантажити pdf Технічний паспорт для Мікрохвильова піч KitchenAid KHHC2090SSS - Architect II 2.0 cu. ft. 1200 W. KitchenAid KHHC2090SSS - Architect II 2.0 cu. ft. 1200 W 1 сторінка. Installation guide
Також для KitchenAid KHHC2090SSS - Architect II 2.0 cu. ft. 1200 W: Інструкція користувача (9 сторінок), Інструкція з монтажу Посібник з монтажу (12 сторінок)

KitchenAid KHHC2090SSS - Architect II 2.0 cu. ft. 1200 W Технічний паспорт
PRODUCT MODEL NUMBERS
KHHC209OS
Electrical: A 120-volt, 60-Hz, AC-only, 15- or
20-amp electrical supply located in the upper
cabinet as close as possible to the microwave
oven hood. A time-delay fuse or circuit breaker
and separate circuit is recommended.
OVERALL DIMENSIONS
VENTING REQUIREMENTS
Roof venting
roof cap
3-1/4" x 10"
through-the-roof
Recommended standard fittings
3-1/4" x 10"
3-1/4" x 10"
to 6" = 5 ft.
roof cap = 24 ft.
90° elbow
3-1/4" x 10"
45° elbow
6" = 10 ft.
wall cap =
6" = 5 ft.
40 ft.
If the existing vent is round, a rectangular-
to-round adapter must be used and a
rectangular 3" extension vent between the
damper assembly and the adapter must be
installed to prevent sticking of the exhaust
damper.
Because Whirlpool Corporation policy includes a continuous commitment to improve
our products, we reserve the right to change materials and specifications without notice.
®
Microwave Hood Combination
CABINET OPENING DIMENSIONS
69" (175.3 cm) min.
Wall venting
For wall or roof venting methods:
If the wall exhaust method is chosen, be sure that
there is proper clearance within the wall so the vent
fits properly and the damper blade opens fully.
Wall and roof caps must have back-draft damper.
We recommend:
using rigid metal vent.
3-1/4" x 10"
that length of vent and number of elbows should
90° elbow = 25 ft.
be kept to a minimum to provide efficient
performance.
that size of vent should be uniform.
using duct tape to seal all joints in the vent
system.
using caulking compound to seal exterior wall or
3-1/4" x 10"
90° flat
roof opening around cap.
elbow= 10 ft.
two elbows should not be installed together.
We do NOT recommend:
flexible metal vent.
NOTE: If flexible metal vent must be used, calculate
each foot of flexible metal vent as two feet of rigid
metal vent. Flexible metal elbows count twice as
much as standard elbows.
A
30"
(76.2 cm)
min.
33"
(83.2 cm)
typical*
A. 2" x 4" wall stud
B. Grounded 3 prong outlet
wall cap
3-1/4" x 10"
through-the-wall
Dimensions are for planning purposes only. For complete details, see Installation
Instructions packed with product. Specifications subject to change without notice.
B
NOTE: The grounded 3 prong outlet
must be inside the upper cabinet.
*33" (83.2 cm) is typical for 69"
(175.3 cm) installation height. Exact
dimension may vary depending on
type of range/cooktop below.
12" (30.5 cm) min.
13" (33.0 cm) max.
Recommended vent length
Use 3-1/4" x 10" or 6" vent. The total length of the vent system
including straight vent, elbow, transitions, wall or roof caps
must not exceed the equivalent of 140 feet of
3-1/4" x 10" rectangular or 6" diameter round vent. For best
performance, use no more than three 90° elbows. To calculate
the length of system you need, add the equivalent feet for
each vent piece used in the system. See examples below.
3-1/4" x 10" vent system
3-1/4" x 10"
6 ft.
90° elbow
2 ft.
1 - 3-1/4" x 10"
90° elbow
1 - wall cap
8 feet straight
Length of
3-1/4" x 10" system
6" vent system
90° elbows
1 - transition
2 ft.
2 - 90° elbows
1 - wall cap
8 feet straight
Length of 6" system
transition
wall cap
= 25 ft.
= 40 ft.
= 8 ft.
= 73 ft.
6 ft.
wall cap
= 5 ft.
= 20 ft.
= 40 ft.
= 8 ft.
= 73 ft.
Ref. 8206590
04-17-07