A-Collection aFlood LED Slim 1600 Sensor Інструкція з експлуатації

Переглянути онлайн або завантажити pdf Інструкція з експлуатації для Прожектор A-Collection aFlood LED Slim 1600 Sensor. A-Collection aFlood LED Slim 1600 Sensor 8 сторінок. Led

LED floodlight
Instruction Manual
Please read the instruction sheet carefully before use:
1. Main structures and application fields
The enclosure of the LED floodlight is made of glass and aluminum alloy with high purity. Intended for outdoor use.
2. Technical data
Model
aFlood LED Slim 800
aFlood LED Slim 2400
aFlood LED Slim 4000
aFlood LED Slim 1600 Sensor
aFlood LED Slim 4000 Sensor
*IP44 Plug To make it an IP65, a permanent connection is required. Depending on the socket's IP Code, use a plug that achieves at least an IP 44.
Required Installation wire:
Protection Class level:
Input voltage:
Range of mounting heights: 1-3 m
3. Attention
(1) In order to ensure the product works properly, please use the power supply within indicating voltage and current;
(2) Cut off supply before installation or repair
(3) If the external flexible cable or cord of this luminaire is damaged, it shall be exclusively replaced by the manufacturer
or his service agent or a similar qualified person in order to avoid a hazard.
(4) Luminaire suitable for surface mounted direct on normally flammable surface.
(5) If the protective glass is damaged or cracked, do not use the armature and discard it.
(6) The luminaire should be at least 1m distance from projection object
(7) The light source of this luminaire is not replaceable. When the light source reaches its end of life the whole luminaire
shall be replaced.
(8) In case of radiation interference, PIR sensor may be affected, lights will turn on even without induction.
(9)The glass is tempered glass, will form small particles after impact and not cause harm to human body.
4. Instruction for sensor ( Detective Angle 120°)
When somebody pass by the detective range of sensor, the light will turn on automatically. And it will turn off when
there is no continuous action in a setting time. The detective distance, working delay time and sensitive illumination can
be adjusted according to requirement.
1) SENS: Adjust the detective distance of sensor ( 2-8M ).
A. Set it to Max., the longest distance is 8 meters.
B. Set it to Min., the longest detective distance is 2 meters.
2) TIME: Adjust the working delay time (10 seconds - 10 minutes).
A. Set it to MAX., the light will turn off automatically after 10 minutes approximately when there is no continuous action.
B. Set it to Min., the light will turn off automatically after 10 seconds approximately when there is no continuous action.
3) LUX: Sensitive illumination (5-2000LUX)
A. Set it to MAX., the light can turn on automatically when somebody move into the detective range, both in daytime
and at night.
B. Set it to Min., the light will turn on automatically only at night when somebody move into the detective range.
5. Environmental protection
IP Classification Input
Power
IP65*
10W
IP65*
30W
IP65*
50W
IP44
20W
IP44
50W
3G*1.0 mm H05RN-F 300/500V
Class I
AC220-240V 50/60Hz
EN
Weight
Maximum
Projected Area
530G
0.013 m²
830G
0.035 m²
1210G
0.047 m²
670G
0.024 m²
1270G
0.057 m²
1m
Size
125*104*27 mm
209*168*27 mm
237*200*36 mm
189*125*55 mm
287*200*57 mm