① Turn on / off
Turn on: Press \"P / C \" to turn on the machine. Shutdown: Press \"P / C \" to shut down the machine. If the power is insufficient, it will automatically shut down; if the machine does not
work for 5 minutes, it will automatically shut down.
② Working mode setting
Long press \"M \" key to enter the menu interface, short press \"M \" key to switch to MODE option, short press \"▽ \" key to select working mode. \"track \" is the real-time mode, \"Pre. \" is
the preset mode, \"peak \" is the peak mode.
a.Real-time mode
In real-time mode, the LCD screen displays the word track to achieve real-time tracking of torque values. In real-time mode, the LCD screen displays the loading torque value in real time.
b.Preset mode
Under the working interface of torque driver, short press \"▽ \" key to display the preset value, press \"▽ \" key again to set the preset value, when the preset value is adjusted to the
required value, press \"M \" Press Save to exit. When locking in preset mode, when the tightening torque reaches 80% of the preset value, the buzzer and indicator will flash alarm at
intervals, the closer to the preset value, the higher the buzzer and indicator flashing alarm frequency, the higher When setting the value, the buzzer sounds long and the indicator light is
always on. In the preset value mode, the force value will be saved in the peak state. When you need to save the data, you can press the \"M \" key to save the data. When the force value is
zero, the data cannot be saved.
Tip: When the buzzer function is turned on, the buzzer will respond.
c,Peak mode
In peak mode, the LCD screen displays the peak value of the loading torque. When you need to save the peak data, you can short press \"M \" to save the current peak data, and you can
short press \"P / C \" to clear the current peak data.
③ Torque unit switching
Long press \"M \" key to enter the setting menu, short press \"M \" key to switch to UNIT option, short press \"▽ \" key to freely select 4 torque units, short press \"M \" key Save the selected
torque unit and exit the menu.
④ LCD backlight function
Long press \"M \" key to enter the setting menu, short press \"M \" key to switch to LTON option, short press \"▽ \" key to choose to turn on or off the backlight. The number 1 indicates that
the backlight is on, and the number 0 indicates that the backlight is off.
⑤ Data storage, viewing and deleting