alkitronic XE Series Посібник з експлуатації та технічного обслуговування - Сторінка 5
Переглянути онлайн або завантажити pdf Посібник з експлуатації та технічного обслуговування для Водяний насос alkitronic XE Series. alkitronic XE Series 16 сторінок. Battery powered torque multiplier
2.3
Hazard notices
In case of mechanical or electrical damages to the
alkitronic® EAF, Li-Ion rechargeable battery pack
or the alktronic® charger station, the use of the
specific device must be interrupted immediately.
The damaged unit must be inspected mechanical
or electrical damages and safety. Any defects must
be repaired by qualified personnel and before
renewed use.
Before repairing mechanical or electrical compo-
nents or devices always disconnect the recharge-
able power pack and the mains power supply from
the power supply to the power tool.
Protect rechargeable battery packs (1)
against damp and wetness and do not
subject to open fire!
Do not use deformed or defective battery packs! Do
not attempt to open battery packs! Do not touch
or short battery pack contacts! Keep away from
small metal objects that could cause an electrical
short between contacts; a short circuit can cause
fire and physical injury through burns.
A slightly acidic and flammable liquid may seep
out of defective Li-Ion rechargeable batteries!
If the battery liquid comes into contact with hu-
man skin immediately rinse with plenty of water.
If battery liquid comes into contact a human eye
immediately rinse and wash with plenty of water
and consult a physician!
Do not attempt to charge non-rechargeable bat-
teries. Explosion risk!
Do not recharge fully charged batteries!
Do not use the charger station out
of doors. Protect the charger station
against dampness and wet!
Keep children away from the charger station and
the work area!
In case of smoke or fire from the charger station
immediately pull out the electric mains supply
plug!
Do not insert objects in the ventilation slots of the
charger station - risk of electric shock or short circuit!
battery powered torque multiplier
3. Operating the alkitronic® charger station
3.1
1
Plug the main plug into
a suitable outlet. The
warning indicator (4) and
the operation indicator (3)
will light up in sequence
for approx. 1 second; the
built-in fan will run
for approx. 5 seconds.
3.2
Charging: push rechargeable battery pack (1) completely
onto the seat (2). The operating indicator will start to flash
To check the charging level of the battery pack first remove
the pack from the charger and then push the button on the
battery pack.
Trickle charging: If the battery pack is fully charged the
charger statin will switch automatically to trickle charging.
The battery pack can be left in the charger and ready for use
any time. The operating indicator (3) will remain lit
Fault: The warning indicator (4) is lit permanently; the bat-
tery pack is not charged. This is due to the temperature be-
ing too high or too low. Once the battery pack temperature
is between 0°C and 50°C charging is started automatically.
If the warning indicator (4) flashes check for correct seat of
the battery pack, or the battery pack is defective. Immedi-
ately remove the battery pack from the charger.
5
The charger station must only be used if the
mains electrical supply matches the voltage and
frequency specifications on the type label of the
station. The charger station is an electrical device
creating a direct current which can trip simple
residual current circuit breakers (RCCB). Use type
F or better, with a trigger current of no more than
30 mA.
Before using the charger station make sure that
the ventilation slots are not covered or blocked.
The minimum distance to other objects should
at least 5 cm!
Self-test
3
Operation indicator
Starting
2
4
Warning indicator