2.6.1 alkitronic® CLD, CLS, CLS2
During operation, always hold the alkitronic® CL
multiplier in the axial direction (6) towards the nut,
otherwise this increases the risk of deformation /
damage to the standard nut / connector (4) or the
screw / nut which is to be loosened. Furthermore,
a secure counter-support (5) is no longer guaran-
teed. (Fig. 4)
4
wrong
6
Safe support only in the area displayed
For the correct tightening and loosening of screw connec-
tions, the following steps are to be carried out (Fig. 4):
• alkitronic® CL with standard nut / connector (4), place
fully on screw / nut
• The outrigger (DMA) of the alkitronic® CL must absorb
the reaction moment at the height of the standard nut /
connector (4)
• A secure, stable counter support (5) must be ensured
• Always hold the alkitronic® CL in axis (6) to the bolt dur-
ing the process
• After pressing the rocker switch (3) for clockwise rotation,
the motor stops when the desired torque is reached:
a) Counterforce = Motor power
b) Counter torque = Motor torque
c) Predetermined torque is reached
Do not retighten the nut. Because the preset
torque is exceeded and it can lead to dam-
age to the torque multiplier or to the screw /
threaded bolt.
Fig. 4
3
5
correct
wrong
Place on next bolt/nut and start bolting process.
If the torque multiplier is not removable from the bolted
joint (torsional forces caused):
• Release the torque multiplier by changing the direction
of rotation
• Briefly press the rocker switch (3, Fig. 4) - counter-
clockwise rotation. In the case of a bolted joint with a
left-hand thread, the direction of rotation is clockwise,
of course.
This leads to a "run free" of the reaction absorber DMA
For your information:
When loosening a bolted connection, up to 20% higher
torque may be required (loosening torque)!
• Remove the machine, place on the next bolt / nut
• Repeat the tightening procedure
2.6.2 alkitronic® RCL
Insert the support pin (8) completely into the
intended fixture (s) of the alkitronic® RCL housing
to prevent damage to the housing.
6
Secure support only with supporting bolts fully inserted in the
housing shells
The tightening and loosening of bolt connections must be
carried out in principle as with multipliers using an axial
downforce. Due to the radial downforce of the alkitronic® RCL
however, the multiplier is to be operated at a 90 degree angle
to the screw axis (6). The output occurs via a fixed wrench size
(4). In order to reduce to smaller wrench sizes, alkitronic® STA
(7) should be used. A support pin (8) is used as a torque trans-
ducer. A secure, stable counter support (5) must be ensured
(Fig. 5). (See also application drawing Fig. 6.)
8
Fig. 5
7
8
Support
4
5