SINGLE ZONE MINI-SPLITS
High Performance Heating
Heating capacity at low
outdoor temperatures is
achieved by adopting a
large heat exchanger
and a high capacity
7
compressor. Systems
operate down to -5°F.
6
Standard Features
Wired Remote Control
W
ired
Weekly Timer
7
7
Dry Mode
6
D
ry
6
6
Auto Mode
POWERFUL
Economy Mode
50 F
Minimum Heat
POWERFUL
Auto Restart/Reset
*Available only with optional wireless remote controller.
^Operation monitoring and On/Off control only.
POWERFUL
Field Supplied Filters Used With Compact Duct Units
Although Compact Duct units come with factory filters, when return
ductwork is used field supplied filters are more practical to use. They
can be installed at the unit or for more convenient servicing, in filter
grilles. See the guidelines to the right to determine filter sizes.
POWERFUL
The chart includes CFM, external static pressure capability and a
typical filter size for each model. Filters are sized to keep velocities
and static pressure loss low. This will insure sufficient static pressure
is available for ductwork, fittings and supply and return grilles.
24
Federal Tax Credit Qualified
$
See Page 9 for details
Systems 9RLFCD and 12RLFCD only.
75°F
When
used
Single
on
Zone
other
models
+5°F
-5°F
7
7
6
7
Auto Changeover
6
L
ow
Low Ambient Cooling
A
mbient
7
Cold Prevention
C
old
Daisy Chain
16
D
aisy
Built-In Condensate Pump
P
ump
I/O
*
Auto
3rd Party Device Control
POWERFUL
3
rd
P
arty
7
6
Alternative filter sizes with equivalent face
areas can be used. After deducting filter
loss, available
static pressure values are shown.
A fiberglass filter is shown in blue
to the left. A MERV pleated filter is
shown in white.
Up to 21.5 SEER
Multi-Tenant
Dwellings
Optional Accessories
Backlit Wired Remote Control
UTY-RVNUM Displays room temp.
Wireless Remote and Receiver
Unit UTY-LRHUM
^
Typical Filter Size
Velocity, FPM
Unit External SP, in. W.C.
SP Loss, in. W.C.
Available Static Pressure
SP Loss, in. W.C.
Available Static Pressure
SP Loss, in. W.C.
Available Static Pressure
Hotels / Motels
Dorms
UTY-RVNUM
ARU
ARU
ARU
9RLF
12RLF
18RLF
CFM
353
353
12 x 20
12 x 20
14 x 25
212
212
0.36
0.36
1" Fiberglass Filter
0.04
0.04
0.32
0.32
1" MERV 8 Pleated Filter
0.12
0.12
0.24
0.24
2" MERV 8 Pleated Filter
0.07
0.07
0.29
0.29
547
225
0.36
0.04
0.32
0.14
0.22
0.08
0.28