FEATURES
Feature Explanation
SEER
Seasonal Energy Efficiency Rating. Used to express efficiency of
an AC or Heat Pump. A higher rating means more efficient.
HSPF
Heating Seasonal Performance Factor, measures the efficiency
of heating portion of your heat pump.
ENERGY STAR
Qualified products and practices help you save money and
reduce greenhouse gas emissions by meeting strict energy
efficiency guidelines set by the U.S. Environmental Protection
Agency and the U.S. Department of Energy.
Apple Catechin Filter (polyphenol ingredient from apples)
Dust, mold spores and microorganisms are absorbed onto the
filter by static electricity and growth is inhibited and deactivated.
3 - 12 month life expectancy, depending on environment.
POWERFUL
Ion Deodorizing Filter
Deodorizes by decomposing absorbed odors using the oxidizing
and reducing effects of ions generated by fine ceramic particles.
3 year life expectancy. Wash to restore surface action.
Sleep Timer
Automatically adjusts the temperature while you sleep to make
you more comfortable.
24 Hour Timer
Allows for one on/off cycle during a 24 hour period.
24 Hour
Weekly Timer
Allows you to set on/off time twice a day and a different on/off
time by day.
7
Dry Mode
7
Helps reduce humidity levels when cooling requirements are low.
D
ry
6
Auto Louver: Up/Down
6
Redirects airflow automatically with seven position up and down
POWERFUL
motion which can be set to auto swing.
Auto Louver: 4 Way
Redirects airflow automatically with up/down and left/right motion.
Auto Fan Mode
System starts in high fan speed and automatically adjusts down-
POWERFUL
ward as room begins to reach set temperature.
7
Powerful Operation
20 minutes of continuous operation at maximum airflow and
7
POWERFUL
POWERFUL
POWERFUL
maximum compressor speed.  Rapid cooling and heating makes
6
the room comfortable quickly.
POWERFUL
POWERFUL
50 F
Minimum Heat Mode
Sets room temperature to 50°F, keeping temperatures above
freezing and reducing power consumption.
Economy Mode
Thermostat setting automatically changes according to the
temperature to avoid unnecessary cooling and heating.
Energy Saver
POWERFUL
7
POWERFUL
Keeps room cool enough for comfort by using a relaxed
thermostat setting reducing power consumption.
6
Energy Saving Program (ESP)
If a space is left without turning the unit off, ESP knows that it is
ESP
unoccupied and 20 minutes later, temperature is adjusted
accordingly until users return to the room.
+Function is bypassed during defrost and at low speed operation. This feature may
limit cooling/heating capacity during high/low ambient conditions and increase energy
consumption as system may need to operate longer due to reduced compressor speed.
12
7
®
Qualified
6
6
7
6
7
6
7
7
6
6
POWERFUL
Quiet Mode (Indoor Unit)
An extra quiet fan speed to make sure you are not disturbed.
Outdoor Unit Low Noise
Limits compressor and fan speed during high speed operation
for a 3 dB noise reduction.+
Power Diffuser
An additional louver that opens based on monitoring sensors to
D
iffuser
quickly enhance immediate comfort needs.
7
Auto Restart/Reset
7
Following a power failure, systems will automatically restart in
6
the same operating mode as before, once power has been
7
restored.
6
Auto Changeover (heating to cooling or vice-versa)
Automatically alternates between heating or cooling if the room
6
temperature falls 4˚F below the set temperature when cooling
or rises 4˚F above set temperature when heating.*
7
Low Ambient Cooling
L
ow
Can operate in cooling mode even when outdoor ambient is
6
A
mbient
0°F, 14°F or 32°F, depending on model, without modification.
Operation outside of factory specification is not recommended.
7
Cold Prevention
Indoor coil will warm prior to fan operating, preventing cold air
7
C
old
during heating mode.
Slender Fit
6
Cassette body can be moved downward into the room 1-3/8"
S
lender
to accommodate limited ceiling space.
POWERFUL
Remote Temperature Sensor
POWERFUL
Room temperature sensor is located in optional wired remote
S
ensor
controller only.
Pump Down Operation
Collects all refrigerant in system back into the outdoor unit
P
D
ump
own
when the unit is to be moved or before servicing the refrigerant
circuit.
7
Daisy Chain
16
Ability to connect up to 16 identical style indoor units to one
D
6
aisy
wired remote.
High Ceiling Mode
Temperature at the top of a high ceiling room may be warmer
C
eiling
than the space occupied; this mode adjusts for this difference.
Branch Duct Capable
7
Systems are capable of attaching field-supplied branch ducts
B
ranch
providing up to 38% of the cooling up to 16 feet away.
Fresh Air Intake
6
Outside air can be introduced by attaching field supplied
flexible duct to fresh air knockouts.
Base Pan Heater
Prevents condensate from freezing on the outdoor unit.
H
eater
I/O
Third Party Device Control
7
Turns system on or off using a normally closed circuit.
3
P
rd
arty
Interface with third party devices such as home automation.
7
6/2
Warranty
Fujitsu systems come with either a 2 Year Parts / 6 Year
W
arranty
Compressor warranty or a 5 Year Parts / 7 Year Compressor
7 7
/5
6
warranty.
W
arranty
6
*Auto Changeover is not designed to provide rapid changes between heating and
cooling operation or simultaneous heating and cooling. This feature is not
recommended for systems with more than one indoor unit unless all indoor units
have similar heating and cooling requirements and have similar temperature set
points. If all indoor units have similar heating and cooling requirements and have