Fujitsu SPARC Enterprise M8000 Примітки до продукту
XCP Issues and Workarounds (Continued)
TABLE 5
ID
Description
RTIF1-
Using the rebootxscf(8) command may
070418-023
result in a process down error, and possibly an
FMA event with MSG ID SCF-8005-NE.
RTIF1-
showaudit all shows a long list of defaults
070418-025
in the policy section after the database is
cleared.
RTIF1-
When you have updated the /etc/ttydefs file of
070528-001
Solaris to disable the console flow control, you
cannot disable the console flow control on the
telnet via a server.
RTIF1-
While XSCF is running, watchdog timeout
070528-002
may occur and XSCF may reboot.
RTIF1-
When connected to telnet, the login or the
070802-001
password prompt doesn't appear.
RTIF1-
When remote power control mode of
070824-001
interlocking mechanism for power supply to
domain, is enabled, after XSCF Unit is
replaced, the interlocking for power supply by
RCI cannot work.
RTIF1-
When the snapshot CLI attempts to write to a
070904-002
USB stick that has write protect set results in
an I/O error.
RTIF1-
An incorrect domain state is reported. After
070904-003
the command sendbreak to domain is issued,
showdomainstatus continues to show the state
as "Running" when the domain is actually at
"ok" prompt.
RTIF1-
The latest communication field in
070904-004
showarchiving is not updated regularly.
Workaround
Ignore this event.
Update the database with the following:
setaudit -a opl=enable
setaudit -a opl=default
None available at this time.
Check that XSCF is started. If not started, use
the rebootxscf(8) command to restart XSCF,
or stop all the domains and then execute the
system power off/on (AC OFF/ON).
Disconnect the telnet session and try again.
After XSCF Unit is replaced, configures the
RCI again and sets the remote power control
mode.
Do not attempt to use write-protected USB
devices for collecting snapshot.
There is no workaround. This is expected
behavior of the sendbreak operation.
Disabling and re-enabling archiving refreshes
the Latest communication field in
showarchiving output.
SPARC Enterprise M8000/M9000 Servers Product Notes