Installation
! Before operating your new appliance please read
this instruction booklet carefully. It contains important
information concerning the safe installation and
operation of the appliance.
! Please keep these operating instructions for future
reference. Make sure that the instructions are kept with
the appliance if it is sold, given away or moved.
! The appliance must be installed by a qualified
professional according to the instructions provided.
! Any necessary adjustment or maintenance must be
performed after the cooker has been disconnected
from the electricity supply.
Compliance with standards
This cooktop must be installed in accordance with the
requirements of local gas and electrical authorities, as
well as the latest published versions of the following
standards:
• AS/NZS 5601 Gas Installation code
• SAA Wiring Rules.
Positioning
! It is possible to install the appliance alongside
cupboards whose height does not exceed that of the
hob surface.
! This cooker should be installed directly on the floor.
Do not install this cooker on an artificial base of any
kind.
! Make sure that the wall in contact with the back of
the appliance is made from a non-flammable, heat-
resistant material (T 90°C).
! Important: Do not install this appliance adjacent to
the door or other means of access to minimise the
likelihood of persons using the door making contact
with pans on the hob surface.
Room Ventilation
Where the total input of all appliances exceeds 3
MJ/h for each cubic metre of the room or enclosure
volume, the space shall be ventilated by one of the
methods detailed below. For the purpose of assessing
the adequacy of ventilation, the space that cannot be
isolated by doors is the 'volume of a room'.
Natural ventilation direct from outside
Two permanent openings shall be provided directly to
outside. The openings shall be located to ensure the
distance between the top of the upper opening and
the ceiling of the room or enclosure, and the distance
between the bottom of the lower opening and the floor
of the room or enclosure does not exceed 5% of the
height of the room or enclosure. The minimum free
ventilation area provided by each opening shall be
calculated using the following formula:
A = 3 × T
where
A = the minimum free ventilation area (cm
T = the total gas consumption of all appliances
(MJ/h)
The minimum vertical dimension of any free ventilation
opening shall be 6 mm.
NOTE 1 When used in this Clause, the term 'directly
to outside' means any one of the following options,
provided that the ventilation path is unobstructed by
building material or insulation:
(a) Directly through an outside wall (preferred
option).
(b) Through to an outside wall but offset.
(c) Into a cavity ventilated to outside.
(d) Into an underfloor space ventilated to outside.
(e) Into a roof space ventilated to outside.
NOTE 2 The two openings may be combined provided
that the top and bottom of the opening reach the limits
set by this Clause.
Natural ventilation via adjacent room
Two permanent openings shall be provided in the room
or enclosure. The openings shall be located to ensure
the distance between the top of the upper opening and
the ceiling of the room or enclosure, and the distance
between the bottom of the lower opening and the floor
of the room or enclosure does not exceed 5% of the
height of the room or enclosure.
The minimum free ventilation area provided by each
opening shall be calculated using the following
formula:
A = 6 × T
where
A = the minimum free ventilation area (cm
T = the total gas consumption of all appliances
(MJ/h)
These requirements shall apply to all subsequent
rooms until a room is ventilated to outside, in
accordance with the previous section, or the total input
of the appliances does not exceed 3 MJ/h for each
cubic metre of the total volume of the enclosure and
rooms.
The minimum vertical dimension of any free ventilation
opening shall be 6 mm.