Cooking zones technical description
Halogen elements
This type of element transmits heat through irradiation
of the internal halogen lamp. One of the main benefi ts
of this type of element is that its properties are similar
to a gas ring: fast response to control adjustments and
instantly visible indication of heating power.
Radiant elements
This type of element is composed of multiple spi-
rals that ensure uniform distribution of heat on the
base of the pan for perfect preparation of foods that
require low heat such as stews, sauces, or when
re-heating previously cooked foods.
Other types of connection
If the electrical system complies with one of the
following characteristics:
Mains voltage, type and frequency
380V + N ~ 50 Hz
230V 3 ~ 50 Hz
380V + 2N ~ 50 Hz
Connect the wires according to the following table
and diagrams:
Mains voltage,
Power cord
type and frequency
400V - 2+N ~
50 Hz
230V 3 ~
50Hz
400V - 2+2N ~
50 Hz
If the electrical system complies with one of the
following characteristics:
Mains voltage, type and frequency 400V 3 - N ~ 50
Hz, proceed as follows:
The power cord supplied cannot be used for this
type of installation.
1. Use a suitable power cord such as H05RR-F
type or higher, of suitable size (cross section: 25
mm).
Service Manual
Hobs - 2006
Key:
H
R
HD = double halogen cooking zone
COOKTOPS
Cooking zone
Right-rear
Right-front
Left-front
Left-rear
Total maximum power
2. Use a screwdriver to press on the tabs that secu-
re the terminal board cover and open the cover
(see fi gure showing Terminal board).
3. Unscrew the cable clamp screw and the screws
of the terminals in relation to the type of con-
nection required, positioning the jumpers in
accordance with the information in the following
table and diagrams
4. Position the wires according to the following table
and diagrams and secure the connections by
Wires connection
tightening the terminal screws fully home.
: yellow/green;
Mains voltage,
N: the 2 blue wires
type and frequency
together
400V 3-N ~
L1: black
L2: brawn
: yellow/green;
5. Secure the power cord in the specifi c cable
N1: blue
clampand close the cover.
N2: blue
L1: black
L2: brown
Edition
2006.03.13
= single halogen cooking zone
= single radiant cooking zone
TVL 641
Power
R 1400 W
H 1800 W
R 1200 W
HD 2500-1050 W
7200 W
Wiring connections
50 Hz
Phase
Jumper
Phase Phase Neutral Earth
G
Terminal board
Three-phase 400
Language
English
B