AEG 2060 D Посібник з експлуатації та встановлення - Сторінка 3

Переглянути онлайн або завантажити pdf Посібник з експлуатації та встановлення для Вентиляційна витяжка AEG 2060 D. AEG 2060 D 19 сторінок. Electrolux cooker hood operating and installation instructions 2060 d
Також для AEG 2060 D: Інструкція з експлуатації та монтажу (20 сторінок), Посібник з експлуатації та встановлення (19 сторінок)

AEG 2060 D Посібник з експлуатації та встановлення

Safety warnings

for user

• Always cover lighted elements, to prevent excess heat from
damaging the appliance. In the case of oil, gas and coal fired
cookers it is essential to avoid open flames.
• Also, when frying, keep the deep frying pan on the cooker top/
cooker under careful control.
• The hot oil in the frying pan might ignite due to overheating.
• The risk of self-ignition increases when the oil being used is dirty.
• It is extremely important to note that overheating can cause a fire.
• Never carry out any flambé cooking under the hood.
• Always disconnect the unit from the power supply before
carrying out any work on the hood, including replacing the
light bulb (take the cartridge fuse out of the fuse holder or switch
off the automatic circuit breaker).
• It is very important to clean the hood and replace the filter at
the recommended intervals. Failure to do so could cause
grease deposits to build up, causing a fire hazard.

for kitchen unit installer

• When used as an extractor unit, the hood must be fitted with a
150mm diameter hose.
• Should there already be a pipe of diameter 125 mm that ducts to
the outside through the walls or roof, it is possible to use the 150/
125 mm reduction flange provided. In this case the hood will be
slightly more noisy.
• When installing the hood, make sure you respect the following
minimum distance from the top edge of the cooking hob/ring
surfaces:
electric cookers
gas cookers
coal and oil cookers
• The national decree on fuel-burning systems specifies a maximum
depression of 0.04 bar in such rooms.
• The air outlet must not be connected to chimney flues or combus-
tion gas ducts. The air outlet must under no circumstances be
connected to ventilation ducts for rooms in which fuel-burning
appliances are installed.
52
600 mm
650 mm
700 mm min.