after terminating cooking.
The control switches are located on the
hood's front panel:
A
B
A
OFF – ON push button
Press once or more to obtain the
function desired:
ON: the hood switches on to the last
speed selected.
OFF: all the functions are switched off
except the illumination.
B
Speed selection push button (extraction
power).
Press this push button once or more
to select the most suitable extraction
speed (power) (1-2-3).
C
The display shows the extraction power
selected, signalling the saturation of the
filters F.
D
Intensive speed on/off. The Intensive
speed runs for 5 minutes:
If the hood is on when the Intensive
speed is activated, the hood reverts to
previous speed after 5 minutes.
If the hood is off when the Intensive
speed is activated, the hood will be
turned off after 5 minutes.
To interrupt the Intensive speed, press
button
A
or
B
.
E
Light ON/OFF
Should the hood or the controls fail to
operate: disconnect the power supply for at
least 5 seconds, then turn the hood back
on again.
Grease and charcoal filter maintenance
indicator
This hood is fitted with a device that
indicates when it is necessary to clean the
grease filter or the charcoal filter (if the
hood is used in the recirculation version
with a charcoal filter).
On delivery, the hood is not supplied with
a charcoal filter, so the saturation indicator
will be disabled.
If the hood is to be used with a charcoal
filter, the saturation
indicator light must be enabled as follows:
C
D
E
Set the hood in "OFF".
Pressing keys
B
and
for three seconds, LED F lights up and
begins to flash the 1st speed led. After 1
second the 2nd speed led also flashes and
the system emits a sound signal (-Beep-) to
indicate setting taking place.
To remove the charcoal filter signal press
push buttons
B
and
3 seconds. LED F lights up and begins to
flash the 1st speed led (grease filter) and
the 2nd speed led. After 1 second, only
the 1st speed led continues to flash. The
system emits a sound signal (-Beep-) to
indicate setting taking place.
Grease filter LED
The 1st speed led (+ led F) flashes, when it
is time to clean the grease filter.
Always comply with the maintenance
instructions for the grease filter.
Charcoal filter LED
The 2nd speed led (+ led F) flashes,
when the charcoal filter needs to be
cleaned or replaced.
Resetting the saturation indicator
After cleaning or replacing the filters, press
button
A
for 3 seconds until the 1st speed
led or the second speed led stops flashing.
The F LED also turns off.
6. LIGHTING
Disconnect the hood from the electricity.
Warning! Prior to touching the light bulbs
ensure they are cooled down.Replace with
a new 12 Volt, 20 Watt (Maximum) halogen
light made for a G-4 base SUITABLE FOR
USE IN OPEN LUMINAIRES. Follow
package directions and do not touch new
light with bare hands.
ENGLISH
D
simultaneously
D
simultaneously for
5