Warranty (cont.)
SPECIAL, INCIDENTAL OR CONSEQUENTIAL DAMAGES. Some
states/provinces do not allow limitations on how long an implied
warranty lasts or the exclusion or limitation of such damages, so
these limitations and exclusions may not apply to you. This warranty
gives the consumer specific legal rights. You may also have other
rights that vary from state/province to state/province. This warranty
is to the original consumer purchaser only, and excludes product
damage due to installation error, product abuse, or product misuse,
whether performed by a contractor, service company, or the
consumer.
This is Kohler Co.'s exclusive written warranty.
*Never use cleaners containing abrasive cleansers, ammonia, bleach,
acids, waxes, alcohol, solvents or other products not recommended
for chrome. This will void the warranty.

Troubleshooting

Symptoms
Probable
Causes
1.
No water
A. Filter is
flow.
plugged.
B. Sensor eyes
are dirty.
C. Water not
turned on.
D. Incorrect
installation.
E. The aerator
is plugged.
F. Sensor eyes
are scratched.
1124214-5-B
Recommended Action
A. Clean or replace the filter.
B. Wipe the sensor eyes with a
damp soft cloth. Wipe dry with a
dry soft cloth.
C. Verify that the water supply is
turned on and that pressure is at
least 20 psi (137 kPa).
D. Verify that the faucet is mounted
as instructed in the installation
guide. Ensure that the sensor eyes
are above the rim of the lavatory.
Refer to the installation
instructions.
E. Remove and clean the aerator.
For calcium/mineral deposits, soak
the plastic insert in a 50:50 mix of
water and vinegar. Soak only the
plastic insert.
F. Replace the sensor assembly.