Kohler 20007A-PNE-NA Інструкція з монтажу Посібник з монтажу

Переглянути онлайн або завантажити pdf Інструкція з монтажу Посібник з монтажу для Сантехнічний виріб Kohler 20007A-PNE-NA. Kohler 20007A-PNE-NA 10 сторінок. Pneumatic in-wall tank with frame short height

THANK-YOU FOR CHOOSING KOHLER COMPANY
We appreciate your commitment to Kohler quality. Please take a few minutes to review this manual before you start installation.
If you encounter any installation or performance problems, please don't hesitate to contact us. Our phone numbers are listed on
the final page. Thanks again for choosing Kohler Company.
BEFORE YOU BEGIN
Read the installation guide carefully and install the product accordingly.
The product information contained in this publication is correct at the time of printing. Kohler Co. reserves the right to
implement changes to this guide, product characteristics, packaging and availability at any time without further notice.
Do not use corrosive cleaners or solvents in or on the tank. This may damage the tank. Mild detergent can be used.
Do not use any spare parts which are not supplied by Kohler. Kohler will not be responsible for any damage due to the
installation of non approved spare parts.
Observe all local plumbing and building codes. Installation shall be in accordance with AS/NZS 3500 and AS/NZS 6400.
WARNING
This product is designed for a water supply pressure range of 20 psi (137kPa) minimum to 72.5psi (500 kPa) maximum.
Any installations where the supply pressure is outside of these limits will not be covered by warranty.
ORDERING INFORMATION
HYDRO-TOWER 200 PNE IWT With Frame 3/4.5 ................................................................................................. 20007A-PNE-NA
PEBBLE Pneumatic In-Wall Tank Faceplate (For Separate Purchase) ...................................................................20341T-PNE-CP
SPECIFICATIONS
Liters per flush
Operating temperature
range
RECOMMENDED TOOLS AND MATERIALS
10'' Adjustable
Wrench
Tubing Cutter
Safety Glasses
1310920-A02-A
20007A-PNE-NA
Environmental temperature:
Water temperature:
Supply
Tape
Shut-off
Measure
Valve
Drill and
assorted bits
HYDRO-TOWER 200
Full flush volume: 4.5L
Half flush volume: 3L
Level
Sponge
Plus:
Connector
Metal File
1/2'' Nut Driver/Socket
Saw
Screwdriver
M8 Coach/TEK Screws x 4
Apprpriate fasteners for masonary
or timber construction.
-1-
INSTALLATION INSTRUCTIONS
PNEUMATIC IN-WALL TANK
WITH FRAME (SHORT HEIGHT)
20007A-PNE-NA
20341T-PNE-CP
Pipe wrench