Kohler 20341T-PNE-CP Інструкція з монтажу Посібник з монтажу - Сторінка 5
Переглянути онлайн або завантажити pdf Інструкція з монтажу Посібник з монтажу для Сантехнічний виріб Kohler 20341T-PNE-CP. Kohler 20341T-PNE-CP 10 сторінок. Pneumatic in-wall tank with frame short height
A3) FACE PLATE/ACVESS PANEL INSTALLATION METHODS
There are four ways to install access panel:
Method one: Press from top
Method two: Remote locking plate installation
Method three: Remote installation of flush button shield
Method four:Press from front: fix four pinch plates with screws
Important: For methods two and three,remote access panel installation a removable panel must be installed either to the top or
front of the cistern access to the cistern parts/valves for maintenance purposes. Fix the cover onto the tank and pull the air hose
to the faceplate.
Method one
A3-1 :Press from top
1. Remove the top cover, then install the rectangular shield on
the top of the tank, and tighten the screw to fix the shield.
2. Cut the cable tie of the air hose and pull it out from
the sheild.
Prepare and finish the wall
IMPORTANT:
a. When preparing the wall, the wallboard/tiling cut-out must fit very neatly
around the square cover of flush panel. No large gaps are permitted
(tolerance of approx 1mm).
b. There may be significant amounts of dust when preparing the wall - ensure
to fit dust cover over cistern opening and protect the electrical fittings and pipework.
c. We recommend before cutting the gib board the toilet is fitted to the frame to
verify the pan height is correct to the finished floor level. Cut the gib board to suit
the position of the flush plate, waste pipe, flush pipe and toilet fixing holes.
Fit the gib board to the stud.
3. Remove the waste pipe and flush pipe cover.
4. Using a sharp knife trim the flush plate sheild back level with the finished wall.
If the finished wall is to be tiled please ensure the thicknass of the tile is included.
The trimmed flush plate shield must sit flush with the finished wall.
5. Fix the locking plate to the flush plate shield using the plastic locking bolts.
When locating the four locking bolts on supporting board, turn the locking
bolts clockwise to the OPEN mark.
1310920-A02-A
Suggested faceplate
Pinch
installation area
plate
R1000mm
Air hose
Method two
Suggested faceplate
installation area
R1000mm
Air hose
Method three
Shield
Screw
Cable tie
Shield
-5-
Pinch plate
Finished
Air hose
wall
At least
80mm gap
required
Method four
Top cover
Front cover
Access panel
Access panel
Flush pipe cover
waste pipe
cover
Locking
plate
Locking
bolt