Kohler C3-230 Посібник із швидкого старту - Сторінка 2

Переглянути онлайн або завантажити pdf Посібник із швидкого старту для Сантехніка для ванної кімнати Kohler C3-230. Kohler C3-230 2 сторінки. Elongated bidet toilet seat with remote control
Також для Kohler C3-230: Посібник із швидкого старту (2 сторінок), Посібник для власників житла (41 сторінок), Посібник із швидкого старту (2 сторінок), Посібник (2 сторінок)

Kohler C3-230 Посібник із швидкого старту
13-1/4"
(337 mm)
Min
18-1/4"
(464 mm) -
1 1 9-1/4"
(489 mm)
15-3/8" (391 mm)
17-1/8" (435 mm)
Required Electrical Service
One dedicated circuit required, protected with Class A Ground-
Fault Circuit-Interrupter (GFCI). Outside North America, this
device may be known as a Residual Current Device (RCD).
Bidet toilet seat:
120 V, 15 A, 60 Hz
Technical Information
All product dimensions are nominal.
Seat shape type:
Elongated
Seat front type:
Closed-front
Seat-mounting
5-1/2" (139 mm)
holes:
Electrical component
Bidet toilet seat: 120 V, 15 A, 60 Hz
rating:
Power cord length:
46" (1168 mm)
1-800-4KOHLER (1-800-456-4537)
Kohler Co. reserves the right to make revisions without notice to product specifications.
For the most current Specification Sheet, go to www.kohler.com.
6-29-2023 00:36 - US/CA
5-1/2"
(140 mm)
8-5/16"
(211 mm)
11-13/16"
(300 mm)
Elongated bidet toilet seat with remote control
6-1/16"
1-3/8"
(154 mm)
(35 mm)
Min
20-7/16"
(519 mm)
1-1/2"
(38 mm)
Notes
Install this product according to the installation
guide.
Connect the seat to a cold water supply of
drinking quality water at a pressure of 20 psi -
80 psi (139 kPa - 551 kPa).
Do not install this seat in a location where: (1)
water might be splashed on the product or
(2) excessive moisture, high humidity levels,
or condensation is present. This will avoid
damage to the electronic components.
CAUTION: Risk of property damage. A single
extension cord may be used provided the cord
"Type" begins with "SJ", 12 gauge, grounded
(12/3), no longer than 25 feet, and plugged into
a GFCI outlet. Promptly replace any extension
cord that exhibits any sign of damage.
To avoid possible product malfunction, do not
plug in the seat until instructed to do so.
Locate the recepticle at least 6" (152 mm)
above the floor, and within a 32" (813 mm)
radius measured 2" (51 mm) from the bowl
ledge.
C³™-230
K-4108
32" (813 mm) R.
2"
(51 mm)
6" (152 mm) Min
Electrical Service Detail