Electrical Installation

Cable Size
Voltage
Power
(AC)
(Watt)
3500
~220V
4500
50/60 Hz
6000
Note: For the correct size of wire conductor corresponding to
different electrical loadings, refer to Cable Size table.
DANGER: Risk of electrical shock. This appliance must be earthed.
Improper grounding could cause electrical shock.
Remember to SWITCH OFF the mains before carrying out any electrical
¨
work. Refer to cable size table for the correct cable size.
Use double insulation cable of over 2.5 mm
¨
Lead the power cable from MCB to a "ON/OFF'' double pole linked switch
¨
(If applicable) having a contact separation of at least 3 mm in all poles
outside the bathroom, then lead a cable to the terminal block inside the
heater unit.
Cut a small groove on the rubber seal "A" (at the back of heater base) with
¨
a cutter for cable inserting.
1237889-X2-G
Current
Cable Size
(A)
15.9
20.5
27.3
FUSE
ON/OFF
12
(mm
)
Switch (A)
2
2.5
2.5
4.0
Fuse Distributor Board
Miniature Circuit Breaker (MCB)
Double PVC cable over 2.5 mm
ON/OFF Double Pole Switch
Cable
.
2
On/Off
Fuse/MCB
(A)
32
32
32
32
32
32
2