Kohler Symbio K-1315-H Посібник з монтажу - Сторінка 8

Переглянути онлайн або завантажити pdf Посібник з монтажу для Сантехніка для ванної кімнати Kohler Symbio K-1315-H. Kohler Symbio K-1315-H 32 сторінки. Bath whirlpool

Bond in accordance
with applicable codes
12. Install the Shower Door (Whirlpool/Receptor Combinations Only)
- Install the shower door according to the instructions packed with the shower door.

13. Make Electrical Connections

NOTE: The whirlpool model number is printed on a label near the whirlpool pump. This label also identifies the
electrical rating of the whirlpool.
WARNING: Risk of electrical shock. To reduce the risk of electrical shock, connect the pump to a properly
grounded, grounding type receptacle protected by a Ground Fault Circuit Interrupter (GFCI). Do not remove
the plug's grounding pin. Do not use a grounding adapter.
- Your Kohler whirlpool bath is equipped with a cord and plug. All wiring of the pump and control has been
completed at the factory. A licensed electrician must install a GFCI protected, 120 V, 20 A, grounded outlet. No
other load should be on this circuit. Locate the outlet behind the whirlpool, and within 24" (61cm) of the pump.
- Plug the pump into this outlet.

14. Install the Whirlpool Trim Kit

- Install the whirlpool trim kit according to the instructions packed with the trim kit. Pay particular attention to the
jet installation steps below - they are very important and are included here to help you obtain smooth,
trouble free jet operation.
NOTE: The jet O ring must be correctly positioned, must be lubricated, and must be in good condition to permit
easy rotation and proper operation of the jet.
- Install the O ring onto the first shoulder of the jet. Lubricate the O ring with silicone lubricant to prevent noisy
operation of the jet.
- Carefully insert the jet into the housing, and lightly push and rotate the jet until it snaps into position. Do not
force the jet.
NOTE: When installed correctly, the jet should turn smoothly both clockwise and counterclockwise.
A
1012312-2-
Install a
GFCI-protected
120 V, 20 A
grounded outlet
Plug the pump
into this outlet
8
Housing
Slide the O-ring
onto the first
shoulder of the jet
Inspect and
lubricate the
O-ring
Insert the jet into the
housing, and lightly
push and rotate until
it snaps in position
Kohler Co.