Kohler COMMAND CV-675-740 Посібник користувача - Сторінка 12
Переглянути онлайн або завантажити pdf Посібник користувача для Двигун Kohler COMMAND CV-675-740. Kohler COMMAND CV-675-740 21 сторінка. Vertical crankshaft
Element Cover Nut
Element
zyxwvu
\
Air
Cleaner
Base
Rubber
I '
Seal
U
\
Stud
CV26 EFI Air
Cleaner Base
:igure 13. Air Cleaner System Components
-
Type B (Commercial Mower).
Service Precleaner
If so equipped, wash and reoil the precleaner every 25
hours of operation (more often under extremely dusty
or dirty conditions).
1. Loosen the cover retaining knob and remove the
cover.
2. Remove the precleaner from the paper element.
3. Wash the precleaner in warm water with
detergent. Rinse the precleaner thoroughly until all
traces of detergent are eliminated. Squeeze out
excess water (do not wring). Allow the precleaner
to air dry.
4. Saturate the precleaner with new engine oil.
Squeeze out all excess oil.
5. Reinstall the precleaner over the paper element.
6. Reinstall the air cleaner cover. Secure cover with
the cover retaining knob.
7.
When precleaner replacement is necessary order
genuine Kohler Parts.
CV17-CV23
CV675, CV25, CV26
I
TYPeA
I
2 4 0 8 3 0 2 4
I
2 4 0 8 3 0 5 4
I
I
Type B
I
45 083 01-S
I
45 083 01-S
I
Service Paper Element
Every 100 hours of operation (more often under
extremely dusty or dirty conditions), replace the paper
element.
1. Loosen the cover retaining knob and remove the
cover.
2. Clean the area around the element to prevent
debris from getting in the engine when element is
removed.
3. Remove the element cover wing nut, element
cover, and paper element with precleaner.
Separate the precleaner from the element and
service as necessary.
4. Do not was the paper element or use
pressurized air, as this will damage the element.
Replace a dirty, bent, or damaged element with a
genuine Kohler element. Handle new element
carefully; do not use if the sealing surfaces are
bent or damaged.
5. When servicing the air cleaner, check the air
cleaner base. Make sure it is secured and not
bent or damaged. Also, check the element cover
for damage or improper fit. Replace all damaged
air cleaner components.
6. Check the condition of the rubber seal on the air
cleaner stud. If it is worn, damaged, or its
condition is questionable in any way, replace it.
12