Kohler Command CV750 Посібник користувача - Сторінка 7
Переглянути онлайн або завантажити pdf Посібник користувача для Двигун Kohler Command CV750. Kohler Command CV750 25 сторінок. Vertical crankshaft engine
Також для Kohler Command CV750: Посібник користувача (8 сторінок), Посібник користувача (24 сторінок)
WARNING: Lethal Exhaust Gases!
Engine exhaust gases contain poisonous carbon monoxide.
Carbon monoxide is odorless, colorless, and can cause death if
inhaled. Avoid inhaling exhaust fumes, and never run the
engine in a closed buildingor confined area.
Cold Weather Starting Hints
1. Be sure to use the proper oil for the temperature
expected. See Figure 3 on page 5.
2. Declutch all possible external loads.
3. Be sure the battery is in good condition. A warm
battery has much more starting capacity than a
cold battery.
4. Use fresh winter grade fuel. NOTE: Winter grade
gasoline has higher volatility to improve
starting. Do not use gasoline left over from
summer.
Starting
1. Place the throttle control midway between the
slow and fast positions. Place the choke control
(non-EFI engines only) into the on position.
2. Start the engine by activating the key switch.
Release the switch as soon as the engine starts.
EFI Engines Only – Initial Starting or After
Running out of Fuel (Dry System).
a. Turn the key switch to the on position for
one minute. Allow the fuel pump to cycle and
prime the system. Turn the key switch off.
b. Turn the key switch to the start position,
crank and start engine.
c. If the engine fails to start, repeat steps a and
b. If the engine does not start after two
priming intervals, contact your Kohler Engine
Service Dealer for further assistance.
NOTE: Do not crank the engine continuously for
more than 10 seconds at a time. If the
engine does not start, allow a 60 second
cool down period between starting
attempts. Failure to follow these
guidelines can burn out the starter
motor.
NOTE: Upon start-up, a metallic ticking may
occur. This is caused by hydraulic lifter
leakdown during storage. Run the
engine for 5 minutes. The noise will
normally cease in the first minute. If
noise continues, run the engine at mid-
throttle for 20 minutes. If noise persists,
take the engine to your local Kohler
Service outlet.
NOTE: If the engine develops sufficient speed to
disengage the starter but does not keep
running (a false start), engine rotation
must be allowed to come to a complete
stop before attempting to restart the
engine. If the starter is engaged while the
flywheel is rotating, the starter pinion
and flywheel ring gear may clash,
resulting in damage to the starter.
If the starter does not turn the engine over, shut
off starter immediately. Do not make further
attempts to start the engine until the condition is
corrected. Do not jump start using another
battery (refer to Battery). See your Kohler Engine
Service Dealer for service assistance.
Carbureted Engines Only:
3. For a Cold Engine – Gradually return the choke
control to the off position after the engine starts
and warms up.
The engine/equipment may be operated during
the warm-up period, but it may be necessary to
leave the choke partially on until the engine
warms up.
4. For a Warm Engine – Return choke to off position
as soon as engine starts.
Stopping
1. Remove the load by disengaging all PTO driven
attachments.
2. For Carbureted Engines Without A Shutdown
Solenoid: Move the throttle to the slow or low
idle position. Allow the engine to run at idle for
30-60 seconds; then stop the engine.
For Carbureted Engines Equipped With A
Shutdown Solenoid: Position the throttle control
between half and full throttle; then stop the
engine.
For EFI Engines: Move the throttle to the slow or
idle position; turn key off to stop engine.
Battery
A 12 volt battery is normally used. Refer to the
operating instructions of the equipment this engine
powers for specific battery requirements.
7