Kohler 1.4BEOR-12V Операція - Сторінка 19

Переглянути онлайн або завантажити pdf Операція для Портативний генератор Kohler 1.4BEOR-12V. Kohler 1.4BEOR-12V 44 сторінки. Heavy duty truck mobile generator sets

9. Alternator (D+) Operation Control Sensor:
A red LED protection.
The Alternator Operation Control Sensor
monitors the correct operation of the DC
alternator
(alternator
malfunction is detected (regulator failure or
driving belt breakage), the LED is illuminated
and the engine will be shutdown automatically
after 3 seconds. In case of failure, the LED will
stay on to indicate the type of failure.
10. Failure to Start Alarm:
A red LED protection.
The LED will flash if there were 5 unsuccessful
starting attempts. The Machine Status Switch
must be switched to the 0 position to clear.
11. Glow Plug Preheating Sensor:
A yellow LED.
Glow plugs are used to preheat the engine as
an aid to starting. The amount of preheating
time will vary depending upon the external
temperature.
during engine preheating.
If the preheating system detects an operation
failure, the yellow LED will start flashing when
the Machine Status Switch is selected.
Note: Start the engine (press the Engine Start
Button) only after the yellow LED for the Glow
Plug Preheating Sensor is switched off.
12. Hourmeter LCD Unit:
The LCD screen.
The Hourmeter LCD Unit displays the system
operation hours. The recording of the hours
begins after the engine is started (green LED
for the Operating Engine Status is on).
13. Service:
A yellow LED.
The service light indicates that the system
needs servicing.
The service interval is preset at every
500 hours.
Contact an authorized distributor/dealer for
correct servicing. Reset the Service light by
pressing and holding the Engine Start Button
for 5 seconds after the engine has been started.
TP-6687
9/10
regulator).
The LED will be illuminated
3.5 Scheduled Maintenance
Functions
The 1.4BEOR has a counter that memorizes the
number of operating hours of the diesel engine. Service
If
a
after 500 hours maximum. The signal reminds the user
to go to an authorized Kohler distributor/dealer to
service the engine.
The 1.4BEOR (while running) has a sensor system
capable of detecting malfunctions in the diesel engine.
In the event of malfunction, the system automatically
shuts down and signals the fault on the corresponding
red LED. Identify and correct the cause of the fault. See
the safety precautions at the beginning of this manual.
Refer to Section 4, Troubleshooting.
Test operate the generator set to verify that the cause of
the shutdown has been corrected.
Section 3 Operation and Use
19