Kohler 6EKOD Інструкція з монтажу

Переглянути онлайн або завантажити pdf Інструкція з монтажу для Портативний генератор Kohler 6EKOD. Kohler 6EKOD 4 сторінки. Marine with adciid controller
Також для Kohler 6EKOD: Інструкція з монтажу Посібник з монтажу (13 сторінок), Інструкція з монтажу Посібник з монтажу (16 сторінок)

Kohler 6EKOD Інструкція з монтажу
Original Issue Date: 11/16
Model: 6EKOD/5EFKOD, 9EKOZD/7EFKOZD, and 11EKOZD/9EFKOZD Marine
Market: Marine with ADCIId Controller
Subject: Circuit Breaker Kit
Introduction
The AC circuit breakers protect the wiring from the
breakers to the vessel's distribution panel. Install the
circuit breaker on the junction box side panel. Contact
an authorized distributor/dealer for application and
selection information.
Safety Precautions
WARNING
Accidental starting.
Can cause severe injury or death.
Disconnect the battery cables before
working
on
Remove the negative (--) lead first
when disconnecting the battery.
Reconnect the negative (--) lead last
when reconnecting the battery.
Disabling the generator set.
cause severe injury or death.
generator set or equipment connected to the set, disable the
generator set as follows: (1) Press the generator set off/reset
button to shut down the generator set. (2) Disconnect the
power to the battery charger, if equipped. (3) Remove the
battery cables, negative (--) lead first. Reconnect the negative
(--) lead last when reconnecting the battery. Follow these
precautions to prevent the starting of the generator set by the
remote start/stop switch.
INSTALLATION INSTRUCTIONS
the
generator
set.
Accidental starting can
Before working on the
WARNING
Hazardous voltage.
Can cause severe injury or death.
Operate the generator set only when
all guards and electrical enclosures
are in place.
Grounding electrical equipment. Hazardous voltage can
cause severe injury or death. Electrocution is possible
whenever electricity is present. Ensure you comply with all
applicable codes and standards.
generator set, transfer switch, and related equipment and
electrical circuits. Turn off the main circuit breakers of all
power sources before servicing the equipment. Never contact
electrical leads or appliances when standing in water or on wet
ground because these conditions increase the risk of
electrocution.
Short circuits.
Hazardous voltage/current can cause
severe injury or death. Short circuits can cause bodily injury
and/or equipment damage.
connections with tools or jewelry while making adjustments or
repairs. Remove all jewelry before servicing the equipment.
TT-1696 11/16
Moving parts.
Electrically ground the
Do not contact electrical