Mounting
®
Remove  the  connectors  on  the  ALARM  inversion  and  programming  jumpers  on  2N
®
Lift1/ 2N
SingleTalk
. Use the 4 screws to loosen and move downwards the audio
unit. Disconnect the speaker and (external) microphone. 
Connect the cable connectors included in the delivery to the microphone and speaker
®
®
connectors on 
2N
Lift1
/ 2N
SingleTalk
 (the microphone and speaker connectors
have  different  sizes  and  cannot  be  interchanged  due  to  the  audio  unit  cover
pictograms). Replace the audio unit cover, move it upwards and tighten the 4 screws.
Put  the  6-pin  connector  on  the  ALARM  inversion  and  programming  jumpers  (see  the
figure below).