5.4
Reverse pulse cleaning (optional)
If the unit is equipped in option with a manual operated reverse pulse cleaning system.
Compressed air is released into the filter dislodging dust and smoke. Through a blue button
on the front of table.
A solenoid-operated air valve discharges a large blast of air through the filter cartridge on
automatic models.
Reverse pulse dislodging particles embedded in the filter media.
If MAXIBENCH is equipped with the optional manually operated reverse pulse cleaning
system, compressed. This is done by depressing a blue button at the front of the table.
5.5
Compressed air connection
Supply 80-90 psi of dry compressed air to the back of the unit.
Quick disconnects and or other connections are to be supplied by end user.
Installation of an air dryer is recommended. Moisture in your air line can damage filter.
Pulse Duration:
For optimal performance, it is recommended that pulsing sequences should be performed 3
times a day on tables in OFF mode.
Note: Neglecting to pulse your filter regularly will reduce filter life.
5.6
Hinged Side Panels (optional)
The MAXIBENCH is equipped with optional right and left, lift-off hinged side panels. Open or remove
panels when working with items too large or awkward for the work surface. Keep the panels closed
under normal operating conditions.

6 START-UP

6.1
Check list
Before starting the collector for the first time, the steps listed below should be followed to ensure
the collector will work properly.
 1. Remove all objects in the vicinity of collector inlet and outlet.
 2. Check for proper installation of all accessories and optional equipment.
 3. Check that all remote controls are wired into the control system, and all service switches are
in the OFF position.
 4. Check that all optional accessories are installed properly and secured.
 5. Turn power ON at source.
 6. Turn the fan motor ON then OFF to check for proper rotation by referencing the rotation
arrow located on the motor's mounting plate.