ELECTRONIC CONTROL PANEL
seconds and then display mode of operation (HEA, COL, AUt or OFF) for two seconds.
DIGITAL DISPLAY
Displays actual Pool/Spa
temperature. In select mode
displays other parameters.
SELECT/SERVICE KEY
Used to select mode of
operation and enter service
mode.
MODE SELECTION
Selecting the desired mode of operation is accomplished by pressing the SELECT KEY.
OFF MODE
Press the SELECT KEY until you reach OFF. Pressing the UP or DOWN key will allow you to
enter either oFF or on mode. When in OFF Mode the display will show actual water temperature
for six seconds and then display OFF for two seconds.
Temperature Setpoint
• Temperature set point maximum for POOL mode is 95°F (35°C).
• Temperature set point maximum for SPA mode is 104°F (40°C).
To change the temperature set point, press the SELECT KEY until you reach either POOL or
SPA. Press either the UP or DOWN key to scroll to your desired temperature set point. Once
your new temperature set point has been reached, release the UP or DOWN key. Your new set
point will be displayed for five seconds, then revert back to the actual pool or spa water
temperature.
Selecting Pool or Spa Mode
Press the SELECT KEY until you reach P_S. Pressing the UP or DOWN key will allow you to
enter either POOL or SPA mode. LED indicator lights will verify the mode selected.
HEAT & COOL MODELS ONLY:
Selecting Heat or Cool or Auto
Press the SELECT KEY until you reach PHC. Pressing the UP or Down key will allow you to
choose P_H for Pool Heat, P_C for Pool Cool or AUt for Auto Mode.
COOL IN THE POOL MODE.
will display actual Pool or Spa water temperature for six
6
POOL LED
indicates pool mode.
ON LED
indicates compressor is on.
SPA LED
indicates spa mode.
INCREASE KEY
DECREASE KEY
NOTE: UNIT WILL ONLY