Long Name
Level
Run Repeak on
Startup
Run Track After
Acquire
Run Track After
Peak
Run Track on
Startup
Step Track Hold Az
Threshold
Step Track Hold El
Threshold
Step Track Hold
Gradient Threshold
Step Track Hold
Noise Threshold
Step Track Hold
Operating Mode
Step Track Hold
Peaking Delay
Tracking Method
AvL Technologies
Type
Value Range
4
Choice
"Yes", "No"
4
Choice
"Yes", "No"
4
Choice
"Yes", "No"
4
Choice
"Yes", "No"
4
Float
4
Float
4
Integer
0-10000
4
Integer
0-10000
"Step Track Only",
"Position Hold
4
Choice
Only", "Step Track"
and "Position Hold"
4
Float
"None",
"StepTrackHold",
4
Choice
<Any other tracking
modules uploaded>
| Proprietary – Content is Subject to Change without Notice
Step Track Hold Tracking
Flag indicating whether the repeak command should
be run on startup if Rx is locked
Flag indicating that the Track Command should run
after a successful acquisition
Flag indicating that the Track Command should run
after a successful peak command
Flag indicating whether the track command should
be run on startup
The amount of pedestal azimuth travel, in degrees,
0.01-2
before Position Hold becomes active.
The amount of pedestal elevation travel, in degrees,
0.01-2
before Position Hold becomes active.
The maximum signal change that will not cause a
peaking decision mistake during step track peaking.
If this value is exceeded by the Current Signal
Gradient (sensor output) then the peaking delay
time will be reset and the antenna will not peak. Set
to 0 to disable the threshold.
The maximum signal variance (noise) that will cause
a peaking decision mistake during step track
peaking. If this value is exceeded by the Current
Signal Noise (sensor output) then the peaking delay
time will be reset and the antenna will not peak. Set
to 0 to disable the threshold.
The mode in which Step Track Hold should operate,
if it is to perform Step Track operations, Position
Hold operations, or both.
The time interval in seconds from the end of the last
peaking cycle to the start of the next peaking cycle.
1-3600
The timer interval restarts at the end of the last
peaking cycle or when the gradient and/or noise
threshold is exceeded.
Tracking Method to use after an Acquisition has
been completed
Description
5