UNPACKING THE WATER COOLER
1.
After unpacking the water cooler, wipe with a soft cloth. Check the unit for evidence of rough handling.
2.
Place the machine on a hard, flat surface. Make certain the unit is level. The unit should not be close to
sources of heat otherwise performance may be affected.
3.
It is best to place the water fountain in an area with good air circulation. Make sure there is at least 75 mm
of space between the back of your fountain and the wall.
WARNING - The drain cap on the back of the unit may become loose during shipping. Fasten the drain
cap tightly before you start to operate the unit. If the drain cap is loose, the unit may leak and cause
floor damage.
INSTALLATION PROCEDURE
The installation must be in accordance with AS/NZS 3500.1 and AS/NZS 3500.2. Pipe jointing is a trade skill and
Aqua Cooler recommends this process is performed by qualified personnel only.
1.
Ensure proper ventilation be allowing 75 mm clearance on each side of the fountain.
2.
Minimum water pressure is 100 kPa and maximum is 700 kPa.
3.
The recommended maximum water inlet temperature is 38°C
4.
Water in connection is secured via a 1/4" push-fit connector on the rear of the unit. It is recommended that
a shut off valve is installed at this point for ease of future maintenance.
5.
Turn on water supply and hold down the taps until a steady stream of water comes from the tap.
6.
Check all connections for water leaks.
7.
Flush fresh mains water through unit for five minutes to ensure any residual water from testing is cleared.
8.
Plug the cooler into the building electrical supply and for the cook and cold model: Switch the cold water
switch to the ON position.
OPERATION
After the water has been connected to the water cooler, the unit is ready for use. Water will flow into the
reservoirs, and then the unit's compressor will start to operate. The first time the water cooler is used, you will
have to wait at least 45 minutes for cold water.
For the cook and cold model:
• To dispense cook (ambient) water, press the cook tap down.
• To dispense cold water, press the cold tap down.