Charging the Battery
New lights should be connected and left in the sun for 1-2 days to ensure battery is charged
before placing in service.
Preferred Installation Location
For best light performance, ensure solar modules are not covered and are in clear view of the
sky with no shadows.
Light Operation
Light is activated by connecting solar module and battery positive and negative wires. Intensity and
flash settings need to be set prior to activation.
1. Unscrew the two socket cap screws located at either side of the light and remove lens cover.
2. Carefully remove internal flasher unit from within the lens cover.
3. The power and range settings of the light are adjusted by setting the DIP switches located on the
top of this internal flasher unit. Your lantern is normally set to maximum range (see 'Selecting an
Intensity Setting' section of this manual).
4. Set rotary switches to the required flash code (see 'Selecting a Flash Code' section of this
manual), also located on the top of the internal flasher unit.
5. Replace internal flasher unit back inside light cover.
6. To activate the light, connect the "Battery Negative (-)" wire to the negative terminal, and the
"Battery Positive (+)" wire to the positive terminal of the battery, and the "Solar Negative (-)" wire
to internal "Solar Negative (-)" wire, and the "Solar Positive (+)" wire to the internal "Solar Positive
(+)" wire.
7. Replace lens cover back onto unit, making sure that wires are not protruding, and screw the two
socket cap screws up tight.
8. To test place dark cover (towel or jacket) on top of light to activate sensor, light will come on.
Care must be taken to observe the polarity of each wire before they are connected.
To ensure waterproofing of the unit, make sure that no wires are protruding and that there is an
even seal when reattaching the lens cover to the unit body.