TroubleShooTinG (continued)
problem
Unit heats but there is little or no
steam produced
and/or
The product requires more steaming
than usual.
Excessive condensation in Food
Compartment.
Steam coming out around top covers
or sides.
possible Cause
Filter Strainer is restricted.
Unit is not being cleaned properly (daily/monthly).
Programming and/or SHO, H2O values were adjusted/
changed improperly.
Insufficient or excessive calcium/mineral deposits on
the Generator surface.
Generator surface is bare.
Generator Steam Ports are
restricted.
Generator Cover is warped or loose.
Generator Diffuser is missing.
Generator surface temperature is too low.
Programming and or SHO and H2O values were
adjusted improperly.
Generator Cover's Wing Nut is loose.
Generator Cover is warped.
10
Corrective action
Check and clean the Filter Strainer as described in
the Maintenance section of this manual.
Clean unit daily and monthly as described in the
Maintenance section of this manual.
Reprogram the SHO and H2O values as described in
the Programming section of this manual.
Verify that thin layer of calcium/mineral deposits
is present on the Generator surface. Refer to the
Maintenance section of this manual.
Generator surface must have a thin calcium/
mineral coating for proper steaming. Refer to the
Maintenance section of this manual.
Clean the Steam Ports as described in the
Maintenance section of this manual.
Verify that the Generator Cover Wing Nut is tight.
If noticeable steam escapes around the Generator
Cover, replace the cover.
Install Generator Diffuser or replace if missing.
Verify Generator surface temperature to be 380–
420°F (193-–215°C).
Reprogram the SHO and H2O values as described in
the Programming section of this manual.
Tighten Wing Nut.
Replace Generator Cover.
P/N 1010881 Rev. F 03/12