System Inspection
The pool circulation system should be frequently inspected
for debris and signs of leaks.
WARNING: Any time the system is opened, air must be
bled from the filter using the air relief valve. Air trapped
in the system can cause an explosion.
1. Ensure pump is OFF. Turn off any automatic controls
and lock out/tag out switches and/or circuit breakers to
ensure the system cannot inadvertently turn on.
WARNING: remove power from system. Disconnect,
lock out/tag power source before attempting to
install, service, relocate or perform any maintenance.
2. Close system isolation valves, if installed.
3. Remove debris from the pool skimmer basket.
4. Open the air relief valve to release pressure in the system.
5. Check system for signs of leaks. If found, consult the
owner's manual of the leaking equipment.
6. Remove pump trap cover and basket and remove debris
according to the pump owner's manual.
Winterizing
Protect the filter from freezing. If possible, take the system
indoors for storage.
1. Turn OFF pump (including automatic controls, lock out/
tag out switches and/or circuit breakers). Ensure system
cannot turn on.
WARNING: Verify power is removed from the system.
Disconnect, lock out/tag power source before
attempting to install, service, relocate or perform any
maintenance.
2. Clean the filter. Refer to the "Cartridge Cleaning" section of
this owner's manual.
7. Replace the pump basket and trap cover according to the
pump owner's manual.
8. Open system isolation valves, if installed.
9. With the air relief valve open, stand clear of the filter and
start the pump.
10. Once a steady stream of water flows from the air relief
valve, close the valve.
NOTICE: Do not over tighten valve. If the valve fails
to seal, turn the pump off, remove the top assembly
and inspect the valve O-Ring. Reset or replace if
necessary.
11. When the system has returned to normal operation,
check the filter operating pressure. If the filter pressure is
8 - 10 PSI above the start-up pressure, the filter needs to
be cleaned. Refer to the "Cartridge Cleaning" section of
this owner's manual.
3. Remove the filter cartridge and store in a warm, dry area.
Protect the cartridge from sunlight.
4. Cover the filter with plastic or a tarp to prevent water from
entering the assembly and freezing.
NOTICE: Failure to follow the above steps could cause
the filter assembly to expand and crack. This will void
the warranty.
AquaGuard | MasterPro