3.1 Timer display during normal operation
Time of Day
Remaining capacity
in litres
When the remaining capacity
Has reached zero
"U 1" means that tank 1
is in "service"
3.2 Set Time of Day
When the valve is in "Service", press either "Set up" or "Set down" (
to adjust the time of day by one digit. Press and hold to adjust several digits.
3.3 Set treated water capacity
1. Checking softening capacity
To calculate softening "capacity"
By dividing index capacity in litres (see Technical data, page 1) with raw
water hardness in
in litres.
From this value 400 litres (regeneration water) is deducted and this new
value is programmed into the timer under 3. below. (See also STEP 3 in
Master programming, page 6).
Example:
Index capacity
Hardness
52 000 - 400 = 2 200 litres to be programmed as capacity.
20