Flue pipes with spigot and socket joints should be fitted with the socket uppermost and all joints should be
sealed with fire cement.
Clearance to combustibles must be adhered to when fitting the flue pipe.
The flue outlet spigot for this appliance is inside the burn chamber during transportation. You can choose
between top or rear outlet from the flue pipe. (Fastening screws are included with the stove).
Flue pipes are placed directly onto the product flue outlet, there are 3 screw holes to secure the flue pipe in
place. See Fig.5.
Note: It is important that the joints are completely sealed using a suitable fire cement. Air leakage etc may lead
to malfunction.
Fig 5
CONNECTING TO A STEEL CHIMNEY
If your installation involves taking the chimney straight up and through the ceiling, you must comply with
National, Local and Building Regulations or flue manufacturers instructions concerning clearances to com-
bustible materials such as walls, floor joists and ceilings. The joint between the stove flue collar and the stove
pipe must also be sealed using the fire cement. It is important that the insulated flue system is properly sup-
ported both at ceiling level and at roof level. THE STOVE MUST NOT BEAR THE WEIGHT OF THE CHIM-
NEY SYSTEM (see chimney manufacturer's instructions). Excessive weight on the stove will
inhibit expansion and could lead to damage of the stove top. Damage caused to the stove in this way would
not be covered by the Manufacturers Warranty.
IN THE EVENT THAT A CHIMNEY FIRE OCCURS RESULTING FROM FAULTY OPERATION OR PRO-
LONGED USE OF DAMP WOOD FUEL, CLOSE THE AIR VENTS COMPLETELY AND CONTACT YOUR
LOCAL FIRE DEPARTMENT IMMEDIATELY.
CAUTION
The chimney should be swept at least twice by a competent and approved person. All chimney joints should
be inspected during cleaning.
FRESH AIR SUPPLY
A solid fuel appliance requires a continuous supply of air to support combustion. If another air using appliance
such as extractor hood or clothes dryer is installed in the same or an adjacent room, the ventilation supply will
need to be increased to ensure there is adequate air for ventilation and combustion when all appliances are in
operation.
In houses equipped with mechanical ventilation an external vent must be installed to provide adequate air for
combustion.
Properly installed solid fuel unit will give even the most efficient houses a pleasant and natural ventilation.
10