Aqua Medic M-Ventil Pulse Посібник з експлуатації - Сторінка 5

Переглянути онлайн або завантажити pdf Посібник з експлуатації для Блок управління Aqua Medic M-Ventil Pulse. Aqua Medic M-Ventil Pulse 6 сторінок.

1. Body of the valve
2. Magnetic reel
3. Power cord
4. CO
-inlet
2
5. CO
-outlet
2
3. Operation with timer
The CO
–consumption during the day (light phase) is determined primarily by the plants. In the
2
night (dark phase), the plants excrete CO
night time, it may even be harmful. The solenoid valve can be linked to a timer to meet these
specific requirements. An elegant solution is to connect the solenoid valve to the timer that
controls the lights. The valve is then switched on and off together with the light.
4. Operation with pH controller
This operation mode should be preferred in comparison to others. It is the most exact and
economical version. Only the exact quantity required is fed into the system. It balances the loss
that is, for example, caused by water movements and aeration. Fluctuations of the pH-values are
avoided by an electronic control. This is an advantage for the creation of a well-balanced
environment.
5. Operation with water
The Aqua Medic solenoid valve may also be used for the control of smaller reverse osmosis
systems. Some important points have to be taken care of to avoid mistakes and damages:
-
The reverse osmosis unit should not exceed a capacity of 150 l/d (35 gpd) of pure water. The
small opening of 2 mm will cause pressure drops and decrease the capacity, if used with larger
systems.
-
If used with tap water, the solenoid valve may be blocked by dirt and rust. In order to avoid
this, several precautions have to be taken:
-
The solenoid valve has to be connected between the sediment filter and the RO module to
protect it from clogging. The storage tank where the water is collected should have a safety
outlet to the drain. If used for marine aquariums, the evaporated water should not be refilled
directly from the RO unit. It is recommended to collect the RO water in a separate tank and to
provide the aquarium from this tank.
The solenoid valve may not be operated with sea water or pure water (reverse osmosis).
–gas. So it is not necessary to provide CO
2
during the
2
5